2. Add 80 ml of DEJET - CLEANER, BASE, VACUUM TOILET SYS-
TEM LINES.
(f) Disconnect the coupling lavatory filling from the RTS rinse valve.
(g) Install the cap on the RTS rinse valve.
(h) Close access panel 194FR.
NOTE: The access door will close only if the RTS service panel
(3) Do the pre-charging of the waste system, as follows:
NOTE: This pre-charging procedure is applicable only to the tempera-
ture condition below than 0 ° C (32 ° F), where there are freez-
ing or icing conditions.
NOTE: Prepare the solution outside the aircraft and use a liquid con-
tainer to transport the solution to the interior of the aircraft.
CAUTION: BE CAREFUL WHEN YOU HANDLE THE INTERIOR
(a) Fill the waste tank, through the toilet bowl, with the solution that follows:
1. 3.8 l of water.
2. Add 200 ml of URBAKTOL AF.
(b) If you prefer, you can use DEJET:
1. 3.95 l of water.
2. Add 80 ml of DEJET - CLEANER, BASE, VACUUM TOILET SYS-
TEM LINES.
D. Job Close-Up
CAUTION: TO PREVENT DAMAGE, EXAMINE ALL THE WORK AREAS
TO MAKE SURE THAT YOU REMOVED ALL TOOLS AND
EQUIPMENT AFTER YOU COMPLETED THE WORK.
(1) Remove from the work area all tools, equipment, and materials that you
used.
EFFECTIVITY: ALL
Copyright © by EMBRAER S.A - All rights reserved - See title page for details.
drain valve is correctly closed.
FURNISHINGS. IF YOU DO NOT OBEY THIS PRECAU-
TION, DAMAGE TO FRAGILE PARTS CAN OCCUR.
GROUND HANDLING AND
SERVICING HANDBOOK
12-15-03-600-801-A/300
Rev.03- FEB 24/11
Page 303