D. Job Close-Up
(1) Close access door 191CR.
(2) Install the pressure-refueling adapter cap.
(3) Disconnect the external DC power supply from the aircraft (GHSH TASK
24-41-00-860-802-A/200).
NOTE: If you set the POWER SELECTION switch to the BATTERY
position on the pressure refueling control panel, set the
POWER SELECTION switch back to the NORM position and
down the guard.
(4) Remove the grounding cable(s) from the aircraft (GHSH TASK 20-40-02-
910-801-A).
EFFECTIVITY: ALL