Embraer EMB-505 Phenom Service Manual page 156

Ground handling and servicing handbook
Table of Contents

Advertisement

• Set the BATT 2 switch to ON.
• Set the BATT 1 switch to ON.
(4) Make sure that the AVAIL lamp in the GPU pushbutton comes on.
(5) Set the GPU pushbutton to the latched (on) position.
Result:
• The AVAIL lamp in the GPU pushbutton goes off.
• The IN USE lamp in the GPU pushbutton comes on.
(6) On the MFD (Multi Function Display), on the ELEC page, make sure that
the electrical synoptic status shows as follows:
Table 201 - ELECTRICAL SYNOPTIC STATUS
BUS/LINE
CENTRAL BUS to DC BUS 1
CENTRAL BUS to DC BUS 2
CENTRAL BUS to DC BUS 2
EFFECTIVITY: ALL
Copyright © by EMBRAER S.A - All rights reserved - See title page for details.
All Buses
GROUND HANDLING AND
SERVICING HANDBOOK
STATUS
Energized
Energized
Energized
De-energized
24-41-00-860-801-A/200
COLOR
Green
Green
Green
White
Page 202
NOV 20/09