(3) Remove the fueling nozzle from the gravity filler neck after you have the
correct fuel quantity in the tank.
D. Job Close-Up
CAUTION: WHEN YOU INSERT THE GRAVITY FILLER CAP INTO THE
GRAVITY FILLER ADAPTER, MAKE SURE THAT THE LAN-
YARD IS CORRECTLY POSITIONED INTO THE ADAPTER.
IF YOU DO NOT OBEY THIS PRECAUTION, THE FILLER
CAP CAN SMASH THE LANYARD AGAINST THE FILLER
ADAPTER.
(1) Close the LH and RH gravity filler caps:
(a) Put the gravity filler cap on the gravity filler neck.
(b) Turn the lever on the gravity filler cap clockwise and then turn the lever down.
(c) Turn the key clockwise to the CLOSE position and remove the key from the
key lock port.
(2) De-energize the aircraft (GHSH TASK 24-41-00-860-802-A/200).
(3) Remove the grounding cable(s) from the aircraft (GHSH TASK 20-40-02-
910-801-A/200).
EFFECTIVITY: ALL
Copyright © by EMBRAER S.A - All rights reserved - See title page for details.