1
ENGINE
PLUG−AIR
INLET
STARTER
GENERATOR
AIR INLET (REF.)
INSTALL THE ENGINE PLUG−AIR INLET TO THE
ENGINE AIR INLET, STARTER GENERATOR AIR
INLET AND STARTER GENERATOR VENT OUTLET.
3
HANDLE
PUT THE PLUG INTO THE CORRECT
POSITION AND PULL IT BACK THROUGH THE
HANDLE.
EFFECTIVITY: ALL
Copyright © by EMBRAER S.A - All rights reserved - See title page for details.
ENGINE AIR INLET (REF.)
STARTER
GENERATOR
VENT OUTLET (REF.)
2
INSTALL THE ENGINE PLUG−EXHAUST
OUTLET PERPENDICULAR TO
THE ENGINE AIR OUTLET.
ENGINE AIR
OUTLET (REF.)
A
Normal Parking - Maintenance Practices
Figure 202 - Sheet 3
GROUND HANDLING AND
SERVICING HANDBOOK
A
ENGINE
PLUG−EXHAUST
OUTLET
10-10-00-500-801-A/200
Rev.01 - MAY 28/10
ENGINE AIR
OUTLET