POST error messages

Table 12. POST error messages
POST message
062
The server failed to boot on three consecutive attempts.
All caches are disabled. Repeatedly turning the server on and then off or resetting the server
might cause this problem.
Action:
If the problem persists, call for service. When the problem is corrected, be sure to enable the
caches.
101 102 106
An error occurred during the system board and microprocessor test.
Action:
114
An adapter read-only memory (ROM) error occurred.
Action:
If you cannot isolate and correct the problem, call for service.
129
An error was detected in the L1 cache of one of the microprocessors.
Action:
If the problem persists, call for service.
Table 11. POST beep codes
1-2-4
RAM refresh verification has failed.
1-3-1
First 64 Kb RAM test has failed.
1-3-2
First 64 Kb RAM parity test has failed.
3-3-1
A memory size mismatch has occurred.
3-3-3
No memory has been detected in the system.
The following tables provide information about the POST error messages that can
appear during startup.
Start the Configuration/Setup Utility program and verify that all settings are
correct. Use the Cache Control selection in the Advanced Setup menu of the
Configuration/Setup Utility program to enable the caches.
Call for service.
Remove the options. If you can start the server without the options installed,
reinstall each option one at a time and retest after each is reinstalled. When an
option fails, replace it.
1. If you just installed a microprocessor, verify that the microprocessor is installed
and seated correctly.
2. If the problem persists, check to see if the system has isolated the problem to a
microprocessor:
If the System Error light on the operator information panel is on, check to
see if the CPU LED on the diagnostic LED panel is on. If it is on, check the
Microprocessor Error LEDs next to the microprocessor sockets.
— If a Microprocessor LED is on, run the diagnostic program for the
— If the microprocessor tests do not fail, call for service.
If no error LED is on, the error logs in the Configuration/Setup Utility
program might provide additional information about the microprocessor
error.
Description
microprocessor indicated by the LED. If the tests fail, replace the
indicated microprocessor.
Reseat the
memory
modules or
install a memory
module. If the
problem
persists, call for
service.
Chapter 4. Solving Problems
73