Table 18. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller
PCNTNW-NW-058 The adapter did not respond to the initialization command.
Explanation: The interrupt request (IRQ) setting might not be valid or the EEPROM
information might be incorrect. Action: Make sure the IRQ settings are correct in the
Configuration/Setup Utility program. for information on setting the interrupt requests. If the
IRQ settings are correct, call for service.
PCNTNW-NW-066 The cable might be disconnected from the adapter.
Explanation: The cable might be disconnected from the server Ethernet port. Action: Verify
that a cable is connected to the Ethernet port.
PCNTNW-NW-071 The matching virtual adapter could not be found.
Explanation: You tried to load another instance of the driver with a different I/O address. This
new adapter could not be found. Action: Verify that you installed an IBM Netfinity 10/100
Fault Tolerant Adapter and make sure that the adapter is seated correctly. If the adapter is
seated correctly, call for service.
PCNTNW-NW-072 A resource tag is unavailable.
Explanation: The driver tried to allocate some resources that were not available. Action: Add
more memory, or free some memory resources in the server. Then, restart the server.
PCNTNW-NW-073 Unable to allocate memory
Explanation: The driver failed to allocate the memory needed for normal operation. Action:
Add more memory, or free some memory resources in the server. Then, restart the server.
PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation: An attempt was made to initialize a given hardware interrupt. The attempt was
not successful. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is
enabled, go to "Starting the diagnostic programs" on page 84 to run the diagnostic programs.
If you have an Ethernet adapter installed, make sure that the adapter does not share an IRQ
with any other device.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the Link Support
Layer (LSL).
Explanation: An error occurred while the driver was trying to register with the LSL. Action:
Check the version of the NetWare or IntraNetWare Operating System. Make sure that this
driver is correct for the version of NetWare or IntraNetWare that you are using. Restart the
server.
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free Count.
Explanation: The MSMTx Free Count is not initialized correctly. Action: Restart the server. If
the problem persists, call for service.
PCNTNW-NW-086 The driver parameter block is too small.
Explanation: The driver parameter block is too small.Action: Restart the server. If the problem
persists, call for service.
PCNTNW-NW-087 The media parameter block is too small.
Explanation: The driver media parameter block is too small.Action: Restart the server. If the
problem persists, call for service.