Replacing The Battery - IBM xSeries 150 User Reference Manual

Hide thumbs Also See for xSeries 150:
Table of Contents

Advertisement

Table 21. UNIX LLI driver messages for the Ethernet controller
pnt0-23
add_intr_handler failed! Vector already occupied.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server. Action: Modify your hardware settings.
pnt0-24
add_intr_handler failed! Vector already shared at different IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server. Action:
pnt0-26
The DMA number is not necessary for PCI device.
Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA setting.
Action: Edit the SPACE.C file to delete the DMA parameter.
The IRQ number is already in use.
pnt0-29
Explanation: The specified I/O address is already in use. Action: Run the NETCONFIG program
to modify your hardware settings.
pnt0-31
I/O address is not necessary for the PCI device.
Explanation: The I/O address specified is not required. Action: Remove the assigned I/O
address specified for the Ethernet controller

Replacing the battery

Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
IBM has designed this product with your safety in mind. The lithium battery must be
handled correctly to avoid possible danger. If you replace the battery, you must
adhere to the following instructions.
Note:
In the U.S., call 1-800-IBM-4333 for information about battery disposal.
If you replace the original lithium battery with a heavy-metal battery or a battery with
heavy-metal components, be aware of the following environmental consideration.
Batteries and accumulators that contain heavy metals must not be disposed of with
normal domestic waste. They will be taken back free of charge by the manufacturer,
distributor, or representative, to be recycled or disposed of in a proper manner.
To order replacement batteries, call 1-800-772-2227 within the United States, and 1-
800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada, call your
IBM reseller or IBM marketing representative.
Note:
After you replace the battery, you must reconfigure your server and reset the
system date and time.