IBM xSeries 150 User Reference Manual page 89

Hide thumbs Also See for xSeries 150:
Table of Contents

Advertisement

Table 12. POST error messages
POST message
301 303
An error occurred during the keyboard and keyboard controller test. These error messages also
might be accompanied by continuous beeping.
Action:
Running the diagnostic tests can isolate the server component that failed, but you must have your
system serviced. If the error message remains, call for service.
Note:
602
Invalid diskette boot record
Action:
If the problem persists, call for service.
604
An error occurred during a diskette drive test.
Action:
662
A diskette drive configuration error occurred.
Action:
If the problem persists, call for service.
962
A parallel port configuration error occurred.
Action:
If the problem persists, call for service.
11xx
An error occurred during the system-board serial port test.
Action:
If the POST error message does not reappear, either the serial cable or the device is probably
failing. See the documentation that comes with the serial device for additional testing
information.
If the POST error message reappears, call for service.
Ensure that:
1. Nothing is resting on the keyboard and pressing a key.
2. No key is stuck.
3. The keyboard cable is connected correctly to the keyboard and to the correct
connector on the server.
If you just connected a new mouse or other pointing device, turn off the server and
disconnect that device. Wait at least 5 seconds; then, turn on the server. If the error
message goes away, replace the device.
1. Replace the diskette.
2. If the problem persists, make sure that the diskette drive cables are correctly
and securely connected.
3. If the problem remains, replace the diskette drive.
1. Verify that the Configuration/Setup Utility program correctly reflects the type
of diskette drive that you have installed.
2. Run the diagnostic tests. If the diagnostic tests fail, call for service.
If you removed a diskette drive, make sure that the diskette drive setting is correct
in the Configuration/Setup Utility program. If the setting is not correct, change it.
If you changed a hardware option, make sure that the parallel port setting is correct
in the Configuration/Setup Utility program. If the setting is not correct, change it.
If you have a modem, serial printer, or other serial device attached to your server,
verify that the serial cable is connected correctly. If it is, use the following
procedure:
1. Turn off the server.
2. Disconnect the serial cable from the serial port.
3. Wait five seconds; then, turn on the server.
Description
Chapter 4. Solving Problems
77

Advertisement

Table of Contents
loading

Table of Contents