Menvier Security TS2500 Installation & Programming Manual page 95

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

TS2500 Installation Manual
Hotkey Options
0
Goto User Menu 1
1 = Bell Test
2 = Walk Test
3 = Remote Reset 8 = Silent Set Wards
4 = Change code 0 = Set/Unset Menu
5 = Select Chime
Engineers Menu 2
1
View Circuits
A/C = Scroll up and down
ENT = Toggle text / location
2
Set System Time
B = Toggle BST / GMT
3
Set System Date
4
Change Passcode (Engineers)
5
Alter Chime Circuits
A/C = Scroll up and down
ENT = To edit
1 = Chime tone 1
2 = Chime tone 2
3 = Chime tone 3
0 = Disabled
6
Alter 24hr Group
1 - 8 = Select/deselect wards displayed
A/C = Toggle wards A-H or I-P
B = Select/deselect all wards
7
Print System Log
8
Alter Circuit Wards
A/C = Scroll up and down
ENT = To edit
1 - 8 = Select/deselect wards displayed
A/C = Toggle wards A-H or I-P
B = Select/deselect all wards
9
View System Log
A/C = Scroll up and down
B = Toggle user name / No
B = Toggle event / ward
B = Toggle circuit No / circuit text
A
Start Call Back Sequence
1 = Call Back No 1
2 = Call Back No 2
3 = Call Back No 3
B = Enter number required
ENT = Start call back sequence
B
Reset User Code 1
ENT = Reset user 1 to 5678
C
Set BST/GMT Dates
0
Remote Service Options
B = Toggle Enabled / Disabled
Page
54
6 = 24hr Omit
7 = Omit Circuits
56
56
56
56
57
57
57
58
58
61
61
62
62
Engineers Menu 3
Hotkey Option
1
Program Time Switches
A = Time switch 1 1 = On Time 1
B = Time switch 2 2 = On Time 2
C = Time switch 3 3 = On Time 3
4 = Off Time 1
5 = Off Time 2
6 = Off Time 3
0 = Manually switch output
2
Part Set Groups
1 - 9/0 = Select part set group
ENT = Edit
3
Use On-Line Keypad
4
Edit User Names
A/C = Scroll up and down
ENT = Edit text
5
Part Set Text
1 - 9/0 = Select part set group
ENT = Edit text
6
Circuit Text
A/C = Scroll up and down
ENT = Edit text
7
Custom Text Menu
0 = Reset message 5 = Banner message
1 = Location text
2 = Printer header
3 = Rem reset msg 8 = Aux. Tamper 2
4 = Printer prefix
8
Equipment Outputs
A/C = Scroll up and down
B = Toggle output A / B
9
Built In Tests
Software Version
1 = Voltage
2 = Current
3 = Circuit Resistance
4 = Digicom Outputs (Panel)
5 = Test panel outputs
6 = Test Node outputs
7 = Confirm Network devices
8 = Test Keypad display
9 = View Network devices
A/C = Network errors
A/C = False setting routine
A/C = Test digicom channels (Plug-on)
A
Custom Outputs
B
Custom Circuits
1 - 8 = Select custom output 1 - 8
ENT = Edit
1 = Toggle unset
2 = Toggle part set A/C = Warning required
3 = Toggle set
A/C = Bell required A/C = Log Required
A/C = Digi required
C
Digi-modem Options
1 = Call back No 1
2 = Call back No 2
3 = Call back No 3
4 = Modem password 9 = Internal digicom
5 = Modem site No
0
Activity Count
A/C = Scroll wards
B = Reset counter
Appendices
Page
64
7 = 1st operates on
8 = 2nd operates on
9 = 3rd operates on
64
65
65
65
66
68
6 = Part set banner
7 = Aux. Tamper 1
9 = Modem string
68
70
73
74
A/C = Sounder required
A/C = Trig Custom o/p
75
6 = Program digicom
7 = Digi Baud rate
8 = COM1 Baud rate
0 = Reset digicom
78
91

Advertisement

Table of Contents
loading

Table of Contents