Menvier Security TS2500 Installation & Programming Manual page 53

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

TS2500 Installation Manual
07 Unset ward first (Default)
When the system is part set and a
passcode is entered the "0=UNSET WARDS"
option will be displayed first.
Set ward first
When the system is part set and a
passcode is entered the "0=SET WARDS"
option will be displayed first.
08 Can set with L.F (Default)
The selected wards can be set with a
telephone line fault, however the user will
be asked to confirm this at the time of
setting. Line fault can be assigned to any
ward , see "Equipment Wards" on page 81.
No set with L.F
The selected wards cannot be set with a
telephone line fault.
09 Can set - AC off (Default)
The selected wards can be set with no
mains power. Mains power off can be
assigned to any ward , see "Equipment
Wards" on page 81.
No set - AC off
The selected wards cannot be set when the
mains power is off.
10 Quiet chimes (Default)
The level of the chime tones is determined
by the volume control of the device driving
the loudspeaker. If the device is a XNode
the volume level set by the volume control
pot on the XNode PCB. If the device is the
control panel the volume level is set via the
"Set Volume Level" option, see "Set Volume
Level" on page 85.
Loud chimes
The level of the chime tones is always full
volume.
11 O/P 1 normal (Default)
Panel output 1 (Relay) is normally de-
energised.
O/P 1 inverted
Panel output 1 (Relay) is normally
energised.
12 Digi normal (Default)
The eight digicom outputs on the control
panel switch from +12V to 0V when active
(+ve removed).
Digi inverted
The eight digicom outputs on the control
panel switch from 0V to +12V when active
(+ve applied).
13 4 digit codes (Default)
All system passcodes are 4 digits.
6 digit codes
All system passcodes are 6 digits. When
using 6 digit passcode the last 2 digits of
the passcode are the user number, e.g.
the engineer's passcode is 123400 and the
master user's passcode is 567801.
14 Modem on Com1 (Default)
The panel comms port (JP8) is used for the
modem.
Printer on Com1
The panel comms port (JP8) is used for the
printer.
15 Chime Audible (Default)
Circuits that are programmed as chime will
only generate a chime tone.
Chime Visible
Circuits that are programmed as chime will
generate a chime tone and the remote
keypads will display the circuit that was
triggered.
16 Manual Omits (Default)
Circuits with the omit attribute can only be
omitted via the user omit routine.
Automatic Omits
Circuits with the omit attribute are
automatically omitted if they are still active
when the system is being set.
17 Omit Tampers No (Default)
Tamper faults cannot be omitted by the
user.
Omit Tampers Yes
Tamper faults can be omitted by the user.
18 O/M s mimic cct (Default)
The output modules connected to the
control panel indicate circuit mimic
activations.
O/M s mimic alms
The output modules connected to the
control panel indicate circuit alarm
activations.
Engineer's Menu 1
49