Advertisement

Engineer's Menu 1
13 Ward Exit
Activates when the selected ward is in exit
mode, deactivates when the selected
ward is set.
14 Ward CCTS Omit
Activates when the selected ward has any
circuits omitted, deactivates when all
circuits in the selected ward are reinstated.
15 Ward Access
If configuration option 29 is set to "Access
code only" this output will only activate
when an "Access" type passcode assigned
to the selected ward is entered and will
remain active for the duration of the
"Access Code Time". If configuration option
29 is set to "Access all codes" this output will
activate when any valid passcode
assigned to the selected ward is entered
and will remain active for the duration of
the "Access Code Time".
16 Ward Set Fail
Activates when the selected ward fails to
set, deactivate when the selected ward is
reset.
17 Ward Bell-SCB
Activates when the selected ward is not in
alarm, deactivates when the selected ward
bell triggers. Re-activates when ward bell
duration timer expires.
18 Ward Settling
Activates when the selected ward settling
timer is running.
19 Ward Clear
Activates when the selected ward is clear
of faults when setting, deactivates when
the selected ward has a fault during setting
or when ward is unset.
20 Ward Tamper
Activates when the selected ward detects
a tamper alarm, deactivates when the
selected ward tamper alarm is reset.
21 Ward Reset Req
Activates when the selected ward requires
a "Reset", deactivates when the ward has
been reset.
40
22 Ward Lock-Out
Activates when a security key is active in
the selected ward, deactivates when the
security key is healthy.
23 Ward Chime On
Activates when any circuit in the selected
ward causes a chime tone.
24 Ward 24hr Omit
Activates when the selected ward has one
or more 24hr circuits omitted, deactivates
when the selected ward has all its 24hr
circuits reinstated.
25 Ward Monitor
Activates when a monitored circuit is
triggered in the selected ward and stays
active for the duration of the "Monitor Cct
Time".
26 Ward Alm Abort
Activates for the "Abort Duration" when the
alarm in the selected ward has been
aborted by the user.
27 Ward Exit Flt
Activates when the selected ward has a
fault during the setting procedure,
deactivates when the fault is cleared.
28 Ward Exit/Ent.
Activates when the selected ward is in entry
or exit.
29 Ward Sndr ctl.
Activates when the selected ward is in exit,
entry or alarm.
30 Ward Perimeter
Activates when the selected ward has a
Night Perimeter circuit in alarm, deactivates
when the alarm is reset.
31 Ward Shunted
Activates when the selected ward has one
or more circuit shunted, deactivates when
the circuits are reinstated.
32 Ward Auto set
Activates when the selected high security
ward is unset, deactivates when the high
security ward is set.
33 Always Off
Never activates.
TS2500 Installation Manual