Engineer's Menu 1
19 Log Time & Date (Default)
The system log will show the time and date
in the following format: "17:10.57 25/12"
where 25/12 is the 25 December.
Log Time & Day
The system log will show the time and day
in the following format: "17:10.57 Wed 25"
where Wed is Wednesday and 25 is the
date.
20 Global Setting (Default)
The user can set their allocated wards from
any remote keypad.
Local Setting
The user can only set their allocated wards
from a remote keypad assigned to their
wards.
21 Global Unsetting (Default)
The user can unset their allocated wards
from any remote keypad.
Local Unsetting
The user can only unset their allocated
wards from a remote keypad assigned to
their wards.
22 24hr Omit Global (Default)
Any 24hr circuit or group can be omitted
from any remote keypad.
24hr Omit Local
Only 24hr circuits or group that are
assigned to the same wards as the remote
keypad can be omitted.
23 Ward bell time (Default)
The system uses the respective "ward bell
delay" and "ward bell duration" timers when
the system is full or part set.
Global bell time
When the system is part-set the respective
"ward bell delay" and "ward bell duration"
timers are used. When the system is full set
the system uses the "global bell delay" and
"global bell duration" timers.
24 Latching Fire (Default)
Fire detection circuits will cause an alarm
when triggered and will only be re-armed
after a full reset, i.e. Enter passcode to
silence alarm, then enter passcode
followed by [ESC] to reset the alarm.
50
Nonlatching Fire
Fire detection circuits will cause an alarm
when triggered. On entering a passcode
the alarm is silenced, if the same circuit is
activated before carrying out a reset, the
alarm re-triggered.
25 Online Printing (Default)
Events recorded in the system log are also
sent to the printer port.
Offline Printing
Events recorded in the system log are not
sent to the printer port.
26 Timed code o/p (Default)
The "User Code Accepted" output types are
timed for the duration of the "Access code
time".
Latched code o/p
The "User Code Accepted" output types are
activated when user passcode is entered
and de-activated when the passcode is re-
entered.
27 Activity flt ok (Default)
Users can set their wards with circuits
flagged as inactive.
Acitivity flt Bar
Users cannot set the system whilst circuits
are flagged as inactive (forced walk test).
28 Latching 24hr (Default)
24 hour detection circuits will cause an
alarm when triggered and will only be re-
armed after a full reset, i.e. Enter passcode
to silence alarm, then enter passcode
followed by [ESC] to reset the alarm.
Nonlatching 24hr
24 hour detection circuits will cause an
alarm when triggered. On entering a
passcode the alarm is silenced, if the same
circuit is activated before carrying out a
reset, the alarm re-triggered.
29 Access code only (Default)
The "System Access" and "Ward Access"
output types are triggered only when a
"Access" type passcode is entered.
Access all codes
The "System Access" and "Ward Access"
output types are triggered when any
passcode is entered.