Menvier Security TS2500 Installation & Programming Manual page 41

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

TS2500 Installation Manual
40 Time Switch 1 On
This output is controlled by the settings of
"Time Switch 1" , see "Time Switches" on
page 64.
41 Time Switch 2 On
This output is controlled by the settings of
"Time Switch 2" , see "Time Switches" on
page 64.
42 Time Switch 3 On
This output is controlled by the settings of
"Time Switch 3" , see "Time Switches" on
page 64.
43 Access Code
If configuration option 29 is set to "Access
code only" this output will only activate
when an "Access" type passcode is
entered and will remain active for the
duration of the "Access Code Time". If
configuration option 29 is set to "Access all
codes" this output will activate when any
valid passcode is entered and will remain
active for the duration of the "Access Code
Time".
44 Payment Required
Activates when the "Payment Time" has
expired, deactivates when engineer resets
the system.
45 Battery Test On
Activates during the battery test and for the
duration of the "Battery Test" duration.
46 Rem Service Call
Activates when the system is on-line with a
remote PC and the Lineload software.
47 System Full Set
Activates when all defined wards are set,
deactivates when any ward is unset.
48 24hr Omit Active
Activates when the 24Hr omit group is
omitted, deactivates when the 24Hr group
is reinstated.
49 PC Output 1 On
This output is controlled by a PC with
Lineload software.
50 PC Output 2 On
This output is controlled by a PC with
Lineload software.
51 PC Output 3 On
This output is controlled by a PC with
Lineload software.
52 PC Output 4 On
This output is controlled by a PC with
Lineload software.
53 Service Required
Activates when the "Service Time" has
expired, deactivates when the engineer
passcode is entered.
54 Reset Required
Activates when the system requires an
"Engineer Reset", deactivates when the
system is reset either by the engineer or
Remote Reset.
55 Always Off
This output never activates
56 Duress Alarm
Activates when a duress code is entered,
deactivates when the duress alarm is reset.
57 System Part Set
Activates when any part of the system is
set, deactivates when all wards are unset or
the system is fully set.
58 Battery Fault
Activates when a battery fault occurs,
deactivates when the fault is cleared.
59 Set Failed
Activates when any ward fails to set,
deactivates when the set fail condition is
reset.
60 System Open
Activates when the system is unset,
deactivates when any part of the system is
set.
61 Shunt code
Activates for 5 seconds when a shunt code
is entered.
62 Random Output On
Activates randomly (between 5 and 60
minutes).
63 Modem Lockout
Activates when the modem is locked-out
(four failed attempts), deactivates when a
master code is entered or after 4 hours.
Engineer's Menu 1
37