Engineer's Menu 1
14 Circuits Omitted
Activates when any circuit is omitted ,
deactivates when all circuits are reinstated.
15 Auxiliary Alarm
Activates when any ward auxiliary alarm is
activated, deactivates when all ward
auxiliary alarms are reset.
16 Always on
Active at all times.
17 Bell (SCB)
This is output type 00 inverted.
18 Auxiliary Fuse
Activates when the auxiliary fuse blows.
19 Auto-Setting
Activates for 1 minute prior to any ward
being set automatically.
20 Tamper Alarm
Activates when a tamper alarm is
triggered, deactivates when all tamper
alarms have been reset.
21 Phone Line Fault
Activates when a line fault is detected,
deactivates when the telephone line is
restored.
22 Mains Power Off
Activates when the mains power is
removed from the control panel,
deactivates when the mains power is
restored.
23 Exit / Entry
Activates when any ward is in entry or exit
mode.
24 Test CCTS Failed
Activates when any circuit fails test,
deactivates when reset by the engineer.
25 1st Knock
Activates when any double knock circuit
activates for the first time, deactivates
when the circuit is activated for the second
time or when the system is reset.
26 Digi Failed
Activates for 5 seconds when the digicom
fails to communicate (plug-on only).
27 Digi Successful
Activates for 5 seconds when the digicom
communicates successfully (plug-on only).
36
28 Digi Active
Activates when the digicom is activated,
deactivates when the digicom has finished
communicating (plug-on only).
29 2nd entry only
Activates when any ward starts the second
entry timer, deactivates when the second
entry time expires.
30 Entry Only
Activates when any ward starts its entry
mode, deactivates when the ward is unset.
31 Exit Only
Activates when any ward starts its exit
mode, deactivates when the ward is set.
32 Custom o/p 1 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on
page 73.
33 Custom o/p 2 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on
page 73.
34 Custom o/p 3 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on
page 73.
35 Custom o/p 4 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on
page 73.
36 Custom o/p 5 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on
page 73.
37 Custom o/p 6 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on
page 73.
38 Custom o/p 7 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on
page 73.
39 Custom o/p 8 on
Activates when a combination of output
conditions occur, see "Custom Outputs" on
page 73.