Engineer's Menu 1
64 Auxiliary 1 tamp
Activates when auxiliary tamper 1 is
activated, deactivates when the alarm is
reset.
65 Auxiliary 2 tamp
Activates when auxiliary tamper 2 is
activated, deactivates when the alarm is
reset.
66 Bell box tamper
Activates when the bell tamper is triggered,
deactivates when the alarm is reset.
67 Panel lid tamper
Activates when the panel lid tamper is
activated, deactivates when the alarm is
reset.
68 Chime Mimic
Activates for 2 seconds when any chime
circuit is activated.
69 24hr CCT Omitted
Activates when any 24Hr circuit is manually
omitted, deactivates when all omitted
circuits are reinstated.
70 Monitored O/P On
Activates when a monitored circuit is
triggered and stays active for the duration
of the "Monitor Cct Time".
71 Alarm Abort
Activates for the duration of the "Abort
duration" timer when the alarm has been
aborted by the user .
72 Code Lock 1 on
Activates when "Code lock timer 1" is on,
deactivates when the timer is off.
73 Code Lock 2 on
Activates when "Code lock timer 2" is on,
deactivates when the timer is off.
74 Code Lock 3 on
Activates when "Code lock timer 3" is on,
deactivates when the timer is off.
75 Rem call enabled
Activates when a user enables remote
service call, deactivates when a user
disables remote service call or after four
hours.
38
76 Auto-set timer 1
Activates when the "Auto-set timer 1" is on,
deactivates when timer is off.
77 Auto-set timer 2
Activates when the "Auto-set timer 2" is on,
deactivates when timer is off.
78 Auto-set timer 3
Activates when the "Auto-set timer 3" is on,
deactivates when timer is off.
79 Relearn Required
Activates when the system requires a
relearn, deactivates when the relearn has
been performed.
80 Custom cct 1
Activates when the custom circuit 1 is
triggered, deactivates when custom circuit
1 is reset.
81 Custom cct 2
Activates when the custom circuit 2 is
triggered, deactivates when custom circuit
2 is reset.
82 Custom cct 3
Activates when the custom circuit 3 is
triggered, deactivates when custom circuit
3 is reset.
83 Custom cct 4
Activates when the custom circuit 4 is
triggered, deactivates when custom circuit
4 is reset.
84 Custom cct 5
Activates when the custom circuit 5 is
triggered, deactivates when custom circuit
5 is reset.
85 Custom cct 6
Activates when the custom circuit 6 is
triggered, deactivates when custom circuit
6 is reset.
86 Custom cct 7
Activates when the custom circuit 7 is
triggered, deactivates when custom circuit
7 is reset.
87 Custom cct 8
Activates when the custom circuit 8 is
triggered, deactivates when custom circuit
8 is reset.
TS2500 Installation Manual