Menvier Security TS2500 Installation & Programming Manual page 64

1040 zone intruder alarm control system
Hide thumbs Also See for TS2500:
Table of Contents

Advertisement

Engineer's Menu 2
Event
DURESS CODE ###
ENGINEER ARRIVES
ENGINEER DEPARTS
ENTRY ####
ENTRY TIME-OUT:-
ENTRY WARDS:-
EXIT CANCELLED:-
EXIT STARTED:-
FACTORY RESTART
FIRE ALARM ####
FIRE WARDS:-
FIRST KNOCK ####
From Remote #,##
Hi Security SET:
LEC #,## TAMPER
LINE RESTORE
LINK ESTABLISHED
LOCK SET UNLOCKED
MAINS POWER OFF
MAINS POWER ON
MENU TIMEOUT ###
MODEM FITTED
MODEM LOCK-OUT
NODE ### R# ADD
NODE ### R# LOST
NODE ### R# TAMP
NODE #,## FUSE
NODE #,## TAMPER
NODE SHUNT ####
ON-LINE ENDED
ON-LINE TO No.#
ON-SITE RESTART
PA ALARM ####
P.A CODE ###
PA WARDS:-
PANEL LID TAMPER
PASSCODE ###
PAYMENT EXPIRED
PC CONNECTED
PC DISCONNECTED
PHONE LINE FAULT
QUICK SET KEY #
Q.SET ABORTED
REARM ON WARDS:-
REINSTATED WARDS
REM #,## TAMPER
REM RESET ACTIVE
REM RESET FAILED
REM SERVICE CALL
RESET WARDS:-
SEC. KEY ####
SERVICE CALL END
SERVICE REQUIRED
SET FAIL WARDS:-
SET FAIL ####
SET NO ACTIVITY
SET WARDS:-
SET WITH L.FLT:-
SETTING DEFERRED
60
Description
Duress alarm from user number ###
Engineer is logged on the system
Engineer is logged off the system
Entry mode started from circuit number ####
Entry mode timed out for wards:- A - P
Entry on wards:- A - P
Exit mode cancelled for wards:- A - P
Exit mode started for wards:- A - P
Factory default loaded
Fire alarm from circuit number ####
Fire alarm on wards:- A - P
First activation of circuit number #### (circuit with Double-Knock attribute)
Quick set perform from remote keypad (# = Network, ## =device No)
Wards A - P set using "High Security" feature
Network #, LEC number ## lid tamper alarm
Telephone line restored to healthy
Remote link via PC established
Lock switch placed in "unlocked" position.
Mains power removed from control panel
Mains power applied to control panel
User number ### entered their passcode and did not selected any functions
Plug-on digi-modem fitted
Modem locked-out (4 failed attempts made via Lineload)
Remote keypad added to XNode
Remote keypad removed from XNode
Remote keypad lid tamper from remote on XNode
TS900 Node fuse failed
TS900 Node lid tamper
Circuits shunted on a Node
Remote service call ended (PC and Lineload)
On-line to remote PC
On-site restart
PA Alarm from circuit number ####
PA code from user number ###
PA alarm on wards:- A - P
Control panel lid tamper
User number ### entered their passcode
System payment timer has expired
PC connected to control panel (PCI/DCI)
PC disconnected from control panel (PCI/DCI)
Telephone line fault detected
Quick set key A, B or C activated
Quick set key aborted
Wards:- A - P re-armed
Wards A - P reinstated
Remote keypad lid tamper
Remote reset via the REM RESET input terminal (RedCARE)
Remote Reset failed
Remote service call in progress
User or engineer has reset wards:- A - P
Security key operated on circuit number ####
Remote service finished
System requires a service visit (Service Timer expired)
Set fail for wards:- A - P
Set fail caused by circuit ####
System was set with inactive circuits (circuits with the activity attribute)
Wards set:- A - P
Wards A - P set with a line fault present
Setting deferred