System Installation
connected to the strobe -ve , the strobe
+ve is connected to [H/O+].
TRG -
This is the bell trigger output which
switches to 0V on alarm and is rated at
500mA. This output can be
programmed for SAB or SCB operation,
and operates as follows:
SAB - Switches to 0V on alarm and
provides a maximum of 500mA.
SCB - Provides a negative hold off
(500mA), which is removed on alarm.
Figure 21. External Sounder Connections
Installing an External Sounder from a
XNode
Both the TS900 Node and XNode have two
programmable outputs, these can be utilised to
drive an external sounder. However, it is
recommended that a remote power supply is
fitted next to the XNode in order to provide
sufficient power for the external sounder. A relay
module such as the Menvier RM3A is also
required to drive the external sounder. The figure
below shows the connection details.
COIL +
COIL -
Aux
12V
COIL +
COIL -
SPARE 1
SPARE 2
TAMPER
TAMPER
NODE
ZX
CIRCUIT X
TX
Program circuit as:
TAMPER with the
INVERT attribute
Aux
0V
Figure 22. External Sounder Connections - Node

Extension Loudspeakers

Control Panel Connections

Up to two extension loudspeakers can be
connected across the [+] and [-] SPEAKER
terminals on the control panel PCB. The volume
for the loudspeaker is controlled via a
28
RLY 2
COM
RLY 2
N/O
RLY 1
N/C
COM
RLY 1
N/O
N/C
SPARE 3
SPARE 4
RM3A
REMOTE
12V
POWER
0V
SUPPLY
programming option, see "Set Volume Level" on
page 85. The control panel loudspeaker can
also be assigned to one or more wards so that it
only operates under relevant conditions.

XNode Connections

Up to two extension loudspeakers can be
connected across the [+] and [-] SPEAKER
terminals on the XNode PCB. The volume for the
loudspeaker is controlled via the "SPEAKER
VOLUME." control. The XNode loudspeaker can
also be assigned to one or more wards so that it
only operates under relevant conditions.

RedCARE or Stand-alone Digicom

A stand-alone digital communicator, RedCARE
STU or Paknet interface card can be connected
to the system to transfer panel status
information to a dedicated Alarm Receiving
Centre.
The control panel has the following outputs for
connection to a digicom/RedCARE:
SAB
Digicom Outputs 1 to 8
MODULE
STROBE-
These are the programmable
STROBE +
TAMPER OUT
digicom/RedCARE output connections. They are
TAMPER IN
TRIGGER
normally at +12V and switch to 0V when active.
+12V
The outputs can be inverted so that they switch
0V
from 0V to +12V when active, see
"Configuration" on page 48. Each output will
source 5mA in the +12V condition and sink
100mA in the 0V condition.
+DC POWER
This provides the +12V power to the
digicom/RedCARE. This output is un-fused and
therefore must only be used if the device is
TS2500 Installation Manual
Figure 23. Loudspeaker Connections