Wiring Diagram Without Thermostat - HAMPTON BAY H35-10 Owners & Installation Manual

Table of Contents

Advertisement

WIRING DIAGRAM WITHOUT THERMOSTAT

WARNING:
Electrical Grounding
Instructions
This appliance is equipped with
a three pronged (grounding)
plug for your protection against
shock hazard and should be
plugged directly into a properly
grounded three-prong recepta-
cle. Do not cut or remove the
grounding prong from this plug.
BATTERY
PACK
1.5V AA type
1.5V AA type
1.5V AA type
RED
1.5V AA type
BLACK
885 PROFLAME
YELLOW/GREEN
ORANGE
PILOT
GREEN
BURNER
This heater does not require a 120V A.C. supply
for operation. In case of a power failure, the re-
mote control/thermostat will continue to operate.
Note:
4 AA Batteries must be installed into the back
up battery compartment however for this unit
to operate when power is lost. See battery
back up instructions in this manual The fan
and or lights will not operate during a power
outage.
SPARK
FLAME DETECT
MAIN ON/OFF
SWITCH
GREY
GREY
BLACK
BROWN
YELLOW
ORANGE
4
6
3
4
SWITCH: SW1
LOAD
PROFLAME 2 IFC CONTROL BOARD
Hampton® H35-10 Direct Vent Freestanding Gas Stove
installation
CAUTION: Ensure that the wires
do not touch a hot surface and are
away from sharp edges.
GREEN
2
BLACK
BLACK
X10
RED
RED
BLACK
BLACK
WHITE
YELLOW
YELLOW
WHITE
X11
|
37
MAIN
LINE
FAN
VARIABLE
LIGHT
37
|

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents