6) Warning Errors (Exx : Serviceman Call Errors)

Error Type
E02 [Maintenance call]
E02-xxx
Description
!!Maintenance!!
Call Service
To reset
Press Reset Key, and also reset the maintenance call value setting by test mode.
display
Error Point
Master counter reached the value set for the maintenance call (value set by test mode). [The
011
message appears when either the power is turned ON, the unit is reset, or when the machine
operation ended.]
Copy counter reached the value set for the maintenance call (value by set test mode). [The
012
message appears when either the power is turned ON, the unit is reset, or when the machine
operation ended.]

7) Warning Errors (Fxx : Others)

Error Type
F01 [No master on print cylinder (drum)]
F01-xxx
Description
No Master on Print Cylinder (Drum)
Make a New Master
To reset dis-
Make a new master with an original.
play
Error Point
015
There is no master on the print drum at the start of printing.
Error Type
F05 [Print quantiy under Minimum Print Quantity]
F05-xxx
Description
Enter Print Quantity Over The Programmed Minimum Value
To reset
Enter print quantity value over the programmed minimum value.
display
Error Point
019
In master making, the print quantity selected is less than the minimum print quantity.
Error Type
F21 [Next Original not set on AF for Multi-Up]
Description F21-xxx
To reset dis-
Set original on the AF.
Or press STOP key (time-out exists for pressing the STOP key).
play
Error Point
032
Next original is not set on AF when multi-up is selected.