Error Type
P08 [Communication error with CI]
P08-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset
Turn the power OFF and ON.
display
Error Point
951
The file is not a correct RINC data.
Error Type
P12 [Master disposal area motor lock]
P12-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset dis-
Press Reset Key.
play
Error Point
301
Master compression motor lock when moving compression plate up.
The master compression HP sensor does not go OFF within 3 seconds after the master compres-
302
sion motor rotates in the reverse direction.
Master compression HP sensor does not go ON within 1 second after the master compression mo-
305
tor operates in the return direction.
Master compression HP sensor does not go OFF within 3 seconds after the master compression
306
motor operates in the compress direction.
Master-compression-motor encoder sensor count did not change as the master compression motor
309
activated in the compress direction and moved out from the home position.
The master compression HP sensor does not go ON even after 1 second after the master compres-
313
sion motor rotates in the compress direction.
Master-compression-motor encoder sensor count did not change within 10 milliseconds after the
316
master compression motor activated.