Furuno FCV-1200L Installation Manual page 55

Color lcd sounder
Hide thumbs Also See for FCV-1200L:
Table of Contents

Advertisement

c) Use [+] or [-] to enter the difference found in b) above. For example, if the indication of the
FCV-1200L is +5
d) Press [ ] or [ ] to close the dialog box.
7. Press [ ] to select TEMP READOUT, and then press [+] to open the dialog box.
OFF
ON
8. Use [-] or [+] to turn the water temperature indication OFF or ON (default setting)
respectively, and then press [ ] or [ ] to close the dialog box.
9. Press [ ] to select TEMP GRAPH, and then press [+] to open the dialog box.
OFF
NARROW STD EXPAND
10. Use [+] or [-] to select the temperature scale graduation interval, and then press [ ] or [ ] to
close the dialog box.
OFF:
No water temperature graph
NARROW: Graduation every 2
STD:
Graduation every 2.5
EXPAND: Graduation every 5.0
11. Press [ ] to select TEMP COLOR and [+] to open the dialog box.
STD
WHITE RED BLACK YELLOW
12. Use [+] or [-] to select the color of the water temperature graph for STD (blue in default
setting but color depends on color setting), WHITE, RED, BLACK or YELLOW as
appropriate, and then press [ ] or [ ] to close the dialog box.
13. Turn the [FUNCTION] switch to EXIT position to quit.
°
higher than the actual value
°
°
(default setting)
°
,
enter –5 (degrees).
3-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcv-1200lm

Table of Contents