Acoustics

All measurements are made in accordance with ISO 7779 and conform with ISO 9296.
Status
Idle (Standby)
Quiet Mode
Printing
Sleep Mode

Operating environment

Environment
Temperature—printer operating
Relative humidity—printer operating
Maximum wet bulb temperature—printer operating
Temperature—printer off
Relative humidity—printer off
Maximum wet bulb temperature—printer off
Temperature—ambient operating environment*
Relative humidity—ambient operating environment*
Temperature—storage and shipping (packaged printer)
with or without print cartridge
Altitude
Atmospheric pressure
Tilt
*In some cases, performance specifications (such as paper OCF, EP cartridge usage) are
measured at an ambient condition.

Scanner specifications

Imaging technology: CCD—Charge coupled device
Scan resolution: 1200 x 600 dpi
Legal flatbed maximum document size: 216 x 356 mm
ADF input capacity: 50 sheets
Dimensions
Weight
1 meter average sound pressure
dBA
16 dBA
50 dBA
55 dBA
16 dBA
60 to 90 °F (16 to 32 °C)
8 to 80%
73 °F (23 °C)
50 to 110 °F (10 to 43 °C)
8 to 80%
80 °F (27 °C)
60 to 90 °F (16 to 32 °C)
8 to 80%
-40 to 110 °F (-40 to 43 °C)
10,000 ft (0 to 3,048 m)
74.6 kPa
Letter, Legal, A4, A5, A6, JISB5, Folio, Officio, Executive,
Statement
2
16–24 lb, 64–90 gm/m
Appendix A: Printer specifications
Declared sound power level (Bels)
Specification
450
3.3 Bels
6.5 Bels
7.0 Bels
3.3 Bels
7016