Transmitter Solutions Dolphin DOLXP1KB Programming & Installation Manual page 36

Vandal resistant back-lit weatherproof access control key and card reader pwith wiegand output & apo data i/o
Table of Contents

Advertisement

Door Forced Open Warning
8 0
& Time
8 1
Propped-up Warning & Time
Egress Delay Warning &
9 0
Alarm
Door Opening Alarm &
9 1
TIMER
Operation Mode & Wiegand
9 4
Output
SYSTEM CODES
Factory Set Master Code
for User to set system in
programming Mode at the
first time.
0 0 0 0
THIS IS NOT A PERMANENT
S Y S T E M C O D E & I T I S
CHANGED IF A NEW MASTER
CODE IS PROGRAMMED.
REFRESH CODE -- Refresh the
9 9 9 9
system and set all its function
back to default values.
DAP CODE-- Direct access
to programming mode. Valid
8 0 8 0
only in the power-up delay
period
USER PINs / Codes whole
group clearance Code - Key
in the Code to clear all the
users in the Location
LOCATIONS:
10--- User Group 1
0 9 9 9
20--- User Group 2
30--- User Group 3
40--- Vistor Group
41--- Duress Group 1
42--- Duress Group 2
43--- Duress Group 3
* *
Exit Programming Code
FUNCTION MODE / TIME:
0---OFF
1-999 Seconds
CODE 1 - FUNCTION MODE:
1---Momentary, No warning
2---Momentary, with warning
3---Momentary, with warning +
Alarm
4---Hold Contact, No warning
5---Hold Contact, with warning
6---Hold Contact, with warning
+ Alarm
CODE 2 - DELAY TIME:
0---No Delay
1-99 Seconds
ALARM TIME:
0---No Alarm
1-999 Seconds
MODES OF WIEGAND OUTPUT
0---Stand Alone Keypad-Valid
Codes & Cards Only
1---Reader-All Codes & Cards
2---Master Keypad-Valid
Codes & Cards only
3---Slave Keypad-Valid Codes
& Cards only
FUNCTION
0000 * *
OR
NEW MASTER CODE
9999 #
8080 #
LOCATION NO.
**
80
FUNCTION / TIME
81
FUNCTION / TIME
90
CODE 1 CODE 2
91
ALARM TIME
94
WIEGAND O/P MODE
CODE ENTRY
* *
0999 #
36
Mode = 0,
#
Door Forced
Open
Warning OFF
Mode = 0,
#
Propped-up
Warning OFF
Mode = 1
Momentary,
#
No warning
TIME = 0
No Delay
#
Time = 0,
No Alarm
#
Mode = 0
Keypad Mode
RESULTS
System in Programming Mode
All programmed data are cleared and
back to the default values except the
Master Code
System in Programming Mode
Whole group of users in the selected
location are cleared
The system back to normal opration
after programming

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents