Duress Codes (For Outputs 1, 2 & 3) - Transmitter Solutions Dolphin DOLXP1KB Programming & Installation Manual

Vandal resistant back-lit weatherproof access control key and card reader pwith wiegand output & apo data i/o
Table of Contents

Advertisement

Example 1: Set a "One Time Visitor Code" with the number of "1 2 6 8" for the Output 1
40 01 00 1268 #
(a)
(a) Visitor Code Programming, (b) The Visitor ID, (c) An One Time Code, (d) The Visitor Code, (e) Entry Confirmation
Example 2: Set a "Visitor Code" with the number of "1 3 7 8" that is valid for three hours for the Output 1
40 02 03 1378 #
(a)
(a) Visitor Code Programming, (b) The Visitor ID, (c) Valid for 3 Hours, (d) The Visitor Code, (e) Entry Confirmation
Example 3: Delete a "Visitor Code" from Vistor ID
40 02 #
(a)
(a) Visitor Code Programming, (b) The Visitor ID, (c) Delete Confirmation
Example 4: Clear all "Visitor Codes" from Location
40 0999 #
(a)
(a) Visitor Code Location, (b) The Deletion Command Code, (c) Confirmation, all Visitor Codes are cleared
DURESS CODES (FOR OUTPUTS 1, 2 & 3)
The Duress Codes are prepared for those Important Persons in case of DURESS while he operates the access control
keypad. The duress code operates like a normal User PIN for Output 1, 2 or 3, and at the same time activates the
Duress Output without any indication. The user may use it to report an emergency and ask for help silently when he is
forced to operate the keypad if the Duress Output is connected with a security system.
NOTE: The Duress Codes are always valid. They are not governed by any inhibit or lock-out function in the system.
OUTPUT LOCATIONS
41
– Duress Codes for Output 1
42
– Duress Codes for Output 2
43
– Duress Codes for Output 3
DURESS CODE IDs
01
50
ID
-
50 Duress Codes Are Allowed for The Output 1
01
10
ID
-
10 Duress Codes Are Allowed for The Output 2
01
10
ID
-
10 Duress Codes Are Allowed for The Output 3
0999
= Clear all the Duress Codes from the selected Location group.
Please see the programming example below for the details.
THE DURESS CODES
50, 10 and 10 Duress Codes can be programmed for Output 1, 2 and 3 respectively. They are stored in their two-digit
Code ID box. When a new Code is put into the same Code ID box, the old code is replaced.
The Duress Codes are 4-8 digits for Manual Mode code entry.
The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry.
Always set a Duress Code that is easy to remember in
used User PIN is highly recommended.
Example: User PIN is 1 3 6 9, then 3 3 6 9 or 1 3 6 0 might be a good choice for the Duress Code.
The Duress Code can also be used to replace the Secondary User PIN or Common User PIN Card reading for the
Duress reporting.
(b)
(c)
(d)
(b)
(c)
(d)
(b)
(c)
(b)
(c)
41
(e)
(e)
02
in the memory
40
LOCATIONS
CODE ID
43
01
-
Panic Situation. Only one number different from the daily
21
(Location 41, 42 & 43)
DURESS CODE
50
-
4-8 DIGITS
VALIDATION
#

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents