The Operation Modes And The Wiegand Output; Wiegand Output At Keypad Operation Mode - Transmitter Solutions Dolphin DOLXP1KB Programming & Installation Manual

Vandal resistant back-lit weatherproof access control key and card reader pwith wiegand output & apo data i/o
Table of Contents

Advertisement

THE OPERATION MODES AND THE WIEGAND OUTPUT

Four operation modes are available for the selection. The codes are 0, 1, 2 and 3.

WIEGAND OUTPUT AT KEYPAD OPERATION MODE

0 --- Stand Alone Keypad Mode -- (Default)
The system provides full functions to operate its outputs and at the same time provides Wiegand Data Output for all
the
VALID Cards and User PINs including the Duress Codes and Visitor Codes. No Wiegand Data Output for the invalid
PINs and Cards.
1 --- Card & Code Reader Mode
In the Card & Code Reader Mode, the keypad provides Wiegand Data Output for all the Card readings and PINs/Card
entries but does not operate its outputs. It is solely a dard and code reader.
NOTE:
It is suggested to clean all the codes and PINs that were previously stored in the system before setting the system for
reader mode.
2 --- Master Keypad of Split-Decoded Mode
The keypad unit provides the Wiegand Data Output for the valid user PINs and Codes exactly like in the Stand Alone
Mode. The Master keypad will transfer all the programmed feature data (except the user PINs, Codes and Card data)
to the Access Controller (decoder) right after it exits the programming mode. A Split-decoded keypad system needs
at least one Master keypad and one Access Controller to work.
3 --- Slave Keypad of Split-Decoded Mode
The Keypad unit provides the Wiegand Data Output for the valid user PINs, Codes and Cards exactly like in Stand Alone
Mode. No feature data is transferred to the Access Controller (decoder) from the Slave keypad. It takes the same
feature data from the Master keypad to operate. The Slave keypad(s) is for a Split-Decoded system that needs more
than one keypads for operation convenience.
NOTE:
a) Do not set more than one keypads in Master mode in a Split-Decoded system. Otherwise, the data will be confused.
b) Each keypad in Split-Decoded mode can be programmed independently with its own user PINs, Codes and Cards.
The Pins, Codes and Cards can be repeatedly used in other keypads in the same system.
LOCATION
OPERATION MODE
94
0
30
(Location 94)
VALIDATION
1
2
3
,
,
or
#
.

Hide quick links: