Product Specifications; Workstation Weights And Dimensions; Environmental Specifications - HP Z240 Maintenance And Service Manual

Workstation
Hide thumbs Also See for Z240:
Table of Contents

Advertisement

Product specifications

Workstation weights and dimensions

Characteristic
Weight
Chassis dimensions
Tower configuration
Chassis dimensions
Converted desktop configuration

Environmental specifications

Characteristic
Temperature
Humidity
Altitude
Shock
Vibration
14
Chapter 1 Hardware overview
Native M.2 connector with PCIe x4 interface
Standard configuration
Minimum configuration
Maximum configuration
Height
Width
Depth
Height
Width
Depth
Operating: 5°C to 35°C (40°F to 95°F)
Non-operating: -40°C to 60°C (-40°F to 140°F)
NOTE:
Derate by 1°C (1.8°F) for every 305 m (1,000 ft) altitude over 1,524 m (5,000 ft).
Operating: 8% to 85% relative humidity, non-condensing
Non-operating: 8% to 90% relative humidity, non-condensing
Operating: 0 to 3,048 m (10,000 ft)
Non-operating: 0 to 9,144 m (30,000 ft)
Operating: ½-sine: 40g, 2-3ms
Non-operating:
½-sine: 160 cm/s, 2-3ms (~100g)
square: 422 cm/s, 20g
NOTE:
Values represent individual shock events and do not indicate repetitive shock events.
Operating Random: 0.5g (rms), 5-300 Hz
Non-Operating: random: 2.0g (rms), 10-500 Hz
NOTE:
Values do not indicate continuous vibration.
Tower
HP Z240 SFF
6.7 kg (14.86 lb.)
5.7 kg (12.66 lb)
7.7 kg (16.93 lb)
33.8 cm (13.3 in)
10.0 cm (3.95 in)
38.1 cm (15.0 in)
10.0 cm (3.95 in)
33.8 cm (13.3 in)
38.1 cm (15.0 in)
HP Z240 SFF and Z240 Tower Workstations
HP Z240 Tower
9.4 kg (20.79 lb)
8.6 kg (18.95 lb)
11.9 kg (26.20 lb)
39.9 cm (15.7 in)
17.0 cm (6.7 in)
44.2 cm (17.4 in)
17.0 cm (6.7 in)
39.9 cm (15.7 in)
44.2 cm (17.4 in)