Control panel message
2E2-Memory Error
2E3-Incompatible Memory Module in Memory
Socket(s) X, X, ...
2E4-DIMM Configuration Warning
2E5-ECC Memory Module Detected on
Unsupported Platform
2E6–Memory Not Configured Correctly for
Proper MEBx Execution
300–Configuration Change Warning
301-Hard Disk 1: SMART Hard Drive Detects
Imminent Failure
302-Hard Disk 2: SMART Hard Drive Detects
Imminent Failure
309 – 30C: Hard Disk 3–6: SMART Hard Drive
Detects Imminent Failure
3F0–Boot Device Not Found
Description
Memory module configuration failed during
boot up.
A memory module in memory socket identified
in the error message is missing critical SPD
information, or is incompatible with the chipset.
The current memory configuration is not
optimized.
Recently added memory module(s) support ECC
memory error correction.
DIMM1 is not installed.
The storage device configuration will be
updated as shown.
Hard drive is about to fail. (Some hard drives
have a hard drive firmware patch that will fix an
erroneous error message.)
Hard drive is about to fail. (Some hard drives
have a hard drive firmware patch that will fix an
erroneous error message.)
Hard drive is about to fail. (Some hard drives
have a hard drive firmware patch that will fix an
erroneous error message.)
Boot device not found.
POST error messages and diagnostic front panel LEDs and audible codes
Recommended action
1.
Ensure memory modules are correctly
installed.
2.
Verify proper memory module type.
3.
Remove and replace the identified faulty
memory module(s).
4.
If the error persists after replacing
memory modules, replace the system
board.
1.
Verify proper memory module type.
2.
Try another memory socket.
3.
Replace with a supported module.
Rearrange the DIMMs so that each channel has
the same amount of memory.
1.
If additional memory was recently added,
remove it to see if the problem remains.
2.
Check product documentation for
memory support information.
Make sure there is a memory module in the
DIMM1 socket and that it is properly seated.
Not applicable
1.
Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
2.
Apply hard drive firmware patch
if applicable. (Available at
http://www.hp.com/support.)
3.
Back up contents and replace hard drive.
1.
Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
2.
Apply hard drive firmware patch
if applicable. (Available at
http://www.hp.com/support.)
3.
Back up contents and replace hard drive.
1.
Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
2.
Apply hard drive firmware patch
if applicable. (Available at
http://www.hp.com/support.)
3.
Back up contents and replace hard drive.
Insert boot device or load operating system.
77