Operation Details
(b) Manual Horizontal vane angle setting
•
By pressing the remote control horizontal airflow direction setting switch, the vane will move to the indicated
position (1, 2, 3, 4, 5, 6, 7) as shown in the table.
•
Horizontal vane angle position
1
Operation
Heating
Cool-
ing
Anti-dew Formation Control
Soft
Dry
Anti-dew Formation Control
Fan
(c) Wide / Spot Airflow Setting
By pressing the remote control WIDE/SPOT switch, the vane will move to position 3 while WIDE and position
2 while SPOT.
For All
Operations
10. QUIET OPERATION
The purpose of this control is to reduce indoor operating noise. Indoor fan speed is set to Lo- when the following
conditions occur.
•
Indoor fan speed is set at Low
•
Indoor heat exchanger temperature rises to 17°C or above
•
Compressor operates for 5 minutes or more
•
Operation frequency is less than 33Hz (CU-G93KE) or 36Hz (CU-G123KE)
This control is cancelled when one of the following conditions occurs.
•
Indoor fan speed is not set at Low
•
Indoor heat exchanger temperature is decreased to 13° C or below
•
Compressor operation frequency is more than 33Hz (CU-G93KE) or 36Hz (CU-G123KE)
2
3
(Left vane position)
1
2
3
4
90°
125°
55°
55°
90°
125°
55°
55°
90°
110°
64°
64°
90°
125°
55°
55°
90°
110°
64°
64°
90°
125°
55°
55°
WIDE
SPOT
3
2
17°C
Indoor Heat
Exchanger Temperature
4
5
5
6
7
1
55°
90°
125°
90°
55°
90°
125°
90°
64°
90°
110°
90°
55°
90°
125°
90°
64°
90°
110°
90°
55°
90°
125°
90°
Lo -
13°C
Lo
– 38 –
CS-G93KE
6
7
(Right vane position)
2
3
4
5
125°
55°
125°
90°
55°
125°
55°
125°
90°
55°
110°
64°
110°
90°
64°
125°
55°
125°
90°
55°
110°
64°
110°
90°
64°
125°
55°
125°
90°
55°
6
7
55°
55°
64°
55°
64°
55°