CS-G93KE
Operation Details
(a) Vertical Airflow Direction Manual
By pressing the remote control vertical airflow direction setting switch, the vane will move to the indicated
angle (1, 2, 3, 4, 5) as shown in the table. When the remote control OFF/ON switch is pressed to stop the
unit, the vane will move to the Close position.
(b) Vertical Airflow Direction Auto
By setting the vertical airflow direction to AUTO, the vane swings up and down from 7° ~ 36° (during Cooling
and Fan) and 3° ~ 33° (during Soft Dry). During Heating operation, the vane angle will shift according to the
indoor heat exchanger temperature as shown below.
B. Horizontal Airflow Direction
(a) Automatic Horizontal Vane angle setting
By setting the horizontal airflow direction to AUTO, the vanes swing left and right from 55° ~ 125° during
Cooling, Soft Dry and Fan operation. During Heating operation, the vane angle will shift according to the
indoor heat exchanger temperature as shown below:
Operation
Heating
Cooling
Soft Dry
Fan
Heating
Indoor heat
exchanger temperature
58°C
33°C
Indoor heat exchanger
temperature
Indoor heat exchanger
temperature
Anti-dew formation control
Anti-dew formation control
Zone C
(125°)
43°C
40°C
Zone B
(90°)
33°C
30°C
Zone A
(55°)
Zone C
(33°)
55°C
Zone B
(70°)
30°C
Zone A
(15°)
Left Vane Position
C
125°
B
90°
A
55°
55° ~ 125°
64° ~ 110°
55° ~ 125°
64° ~ 110°
55° ~ 125°
Left Vane
55°
50°
90°
125°
Stopper position
– 37 –
Right Vane Position
125°
55° ~ 125°
64° ~ 110°
55° ~ 125°
64° ~ 110°
55° ~ 125°
Vane angle position
Right Vane
125° 55°
90°
90°
55°
50°
Stopper position