Operation Details - Panasonic CS-G93KE Service Manual

Table of Contents

Advertisement

CS-G93KE

Operation Details

A. FUNCTIONS
1. TEMPERATURE SHIFT
Once the operation starts, the remote control setting temperature will be shifted internally based on the setting fan
speed and outdoor air temperature. In addition, if Sleep Mode or Powerful Mode are set, the temperature shift will
be carried out.
Setting of Internal Setting Temperature
The internal setting temperature can be decided as follows:
Table a
Setting Temperature Shift based on outdoor air temperature.
(i) Cooling, Soft Dry
38°C ≤ Outdoor air temperature
30°C ≤ Outdoor air temperature < 38°C
23°C ≤ Outdoor air temperature < 30°C
Outdoor air temperature < 23°C
Table b
Powerful Mode Shift.
Remote control setting temperature
Outdoor temperature shift (refer Table a)
Fan speed shift (+ 1.0
Any Sleep Mode shift operation?
Any Powerful Operation shift? (refer Table b)
[Check upper/lower (33°C/16°C) limit for setting temperature]
INTERNAL SETTING TEMPERATURE
Cooling
Powerful
–4.0°C
+
+
°
C)
+
+
+
(ii) Heating
Shift amount
CS-
CS-
21°C ≤ Outdoor air temperature
G93KE
G123KE
17°C ≤ Outdoor air temperature < 21°C
–1.0°C
–1.0°C
13°C ≤ Outdoor air temperature < 17°C
–0.5°C
–1.0°C
9°C ≤ Outdoor air temperature < 13°C
0.0°C
0.0°C
5°C ≤ Outdoor air temperature < 9°C
+1.0°C
+1.0°C
1°C ≤ Outdoor air temperature < 5°C
–3°C ≤ Outdoor air temperature < 1°C
Dry
Heating
–3.0°C
+6.0°C
– 17 –
Outdoor air temperature < –3°C
Shift amount
–1.5°C
–1.0°C
–1.0°C
0.0°C
+0.5°C
+1.0°C
+1.0°C
+1.5°C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-g93keCs-g123keCu-g123ke

Table of Contents