Operation Details
3. SOFT DRY OPERATION
A. Room Temperature Control
At the start of operation, cooling operation is running until the intake air temperature is 0.5°C higher than internal
setting temperature, then the operation will shift to Soft Dry with indoor fan speed SLo.
Soft Dry
Intake air temp. –
Internal setting
temp. (°C)
Internal setting temp.
Compressor OFF temp.
Condition
Model No.
•
Compressor OFF temperature = Compressor ON temperature.
•
The operation frequency changes every 30 seconds.
•
30 minutes from the start of the operation, the compressor is operating at Fc max Hz.
•
The Compressor stops when the intake air temperature reaches 3.5°C below internal setting temperature and continues
for 3 minutes.
•
When the compressor stops operation, indoor fan stops for 330 seconds.
•
When the Compressor stops, it will not begin operation for 3 minutes. (Time Delay Safety Control)
•
When the intake air temperature reaches the Compressor ON temperature, the Compressor starts operation
immediately.
•
When the Compressor stops, the outdoor fan motor stops 30 seconds later.
Cooling Operation
+1.5
+1.0
+0.5
15
0
15
–0.5
15
–3.5
Comp OFF
When the
temperature falls
CS-G93KE
– 20 –
Compressor Operation Frequency (Hz)
Cooling Operation
22
22
15
15
15
Comp OFF
Comp OFF
When the
When the
temperature rises
temperature falls
CS-G93KE
22
22
16
16
15
15
15
15
Comp OFF
When the
temperature rises
CS-G123KE