Quiet Operation (Cooling Mode/Cooling Area Of Dry Mode); Quiet Operation (Heating); Powerful Mode Operation - Panasonic CU-Z20VKE Series Installation Instruction

Indoor/outdoor unit
Hide thumbs Also See for CU-Z20VKE Series:
Table of Contents

Advertisement

14.5 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)

Purpose
To provide quiet cooling operation compare to normal operation.
o
Control condition
Quiet operation start condition
o
When "POWERFUL/QUIET" button at remote control is pressed twice.
QUIET will be shown on remote control display.
Quiet operation stop condition
o
When one of the following conditions is satisfied, quiet operation stops:
POWERFUL/QUIET button is pressed again.
Stop by OFF/ON switch.
Timer "off" activates.
Mild Dry Cooling button is pressed.
FAN SPEED button is pressed.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if timer "on" activates, quiet operation maintains.
After off, when on back, quiet operation is not memorised.
Control contents
Fan speed is changed to Lo-.
o

14.6 Quiet Operation (Heating)

Purpose
To provide quiet heating operation compare to normal operation.
o
Control condition
Quiet operation start condition
o
When "POWERFUL/QUIET" button at remote control is pressed twice.
QUIET will be shown on remote control display.
Quiet operation stop condition
o
When one of the following conditions is satisfied, quiet operation stops:
POWERFUL/QUIET button is pressed again.
Stop by OFF/ON switch.
Timer "off" activates.
Mild Dry Cooling button is pressed.
FAN SPEED button is pressed.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except
fan mode only.
During quiet operation, if timer "on" activates, quiet operation maintains.
After off, when on back, quiet operation is not memorised.
Control contents
Fan speed manual
o
Fan speed is changed to Lo-.
Fan Speed Auto
o
Fan speed is changed to Lo-.

14.7 Powerful Mode Operation

When the powerful mode is selected, the internal setting temperature will shift lower up to 2.0°C (for Cooling/Soft
Dry) or higher up to 3.5°C (for Heating) than remote control setting temperature for 20 minutes to achieve the
setting temperature quickly.