Servicing Information
d.
Cross Flow Fan Removal Procedure
1. Remove Discharge Grille
Fig. 16
1.
Remove Cross Flow Fan
Fig. 17
2 Remove
the screw
3 Release the slot of indoor heat
exchanger from the chassis
Fig. 19
1 Remove the Discharge Grille
3 Pull slightly
4 Remove the Cross Flow Fan
Fig. 18
2 Remove the bushing
– 60 –