Cooling, Dry
Wind direction position image
CS-S18/24/28TKV
Cooling, Dry
Wind direction position image
* The vertical vane angle tolerance is within +/- 5 degree.

12.5 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)

Purpose
To provide quiet cooling operation compare to normal operation.
o
Control condition
Quiet operation start condition
o
When Quiet button at remote control is pressed.
Quiet operation stop condition
o
When one of the following conditions is satisfied, quiet operation stops:
ECONAVI button is pressed.
iAUTO-X button is pressed.
Sleep mode timer delay OFF.
Stop by OFF/ON button.
OFF Timer activates.
Quiet button is pressed again.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if ON timer activates, quiet operation maintains.
After off, when on back, quiet operation is not memorized.
Control content
Fan speed is changed from normal setting to quiet setting of respective fan speed.
o
Fan speed for quiet operation is reduced from setting fan speed.
o
Operation
Automatic
Manual
90°
operation
Operation
Automatic
Manual
90°
operation
Left and Right Vane
1
2
(Wind direction 2 to 5)
65°
Left and Right Vane
1
2
(Wind direction 2 to 5)
70°
73
3
4
77.5°
102.5°
3
4
80°
100°
5
115°
5