12.10 Quiet Operation
(For Cooling Operation or cooling region of Soft Dry Operation)
•
To provide quiet cooling operation condition.
•
Once the Quiet Operation is set at the remote control, the Quiet LED illuminated. The sound level will reduce
around 2dB(A) for Lo fan speed or 3dB(A) for Hi/Me fan speed against the present operation sound level.
•
Dew formation become severe at Quite Lo Cool, therefore Quiet Lo cool operated only for 2 hours (1 hour QLo, 1
hour QLo + 80rpm)(for A9KKD and A12KKD) and Quiet Lo cool operated only 1 hour 30 minutes (1 hour QLo, 30
minutes QLo + 50 rpm) (for A18KKD, A24KKD and A28KKD).
•
Manual Airflow Direction:
RPM control during Lo cool
o
(For A9KKD and A12KKD)
(For A18KKD, A24KKD and A28KKD)
RPM control during Hi & Me cool
o
•
Auto Fan Speed
•
Quiet operation stops when:
Quiet button is pressed again.
o
Stopped by OFF/ON operation button.
o
Timer OFF activates.
o
Operation mode button is changed.
o
62