Panasonic CS-G93KE Service Manual page 24

Table of Contents

Advertisement

CS-G93KE
Operation Details
Deice Operation Time Chart
Outdoor Heat
Exchanger
Temperature (°C)
Compressor operating
frequency
Indoor Fan
Outdoor Fan
4-way valve
• Compressor frequency is set at 40Hz (CU-G93KE) or 49Hz (CU-G123KE) when the deice operation starting signal is
generated.
• 30 seconds later deice operation starting signal is generated, indoor fan, outdoor fan, 4-way valve are turned off and
compressor operates at 40Hz (CU-G93KE) or 49Hz (CU-G123KE) for 30 seconds. (Deice operation starts)
• During deice operation, the compressor operating frequency is set at 58Hz (CU-G93KE) or 83Hz (CU-G123KE).
• Deice will end when the outdoor heat exchanger temperature rises to 16°C or after 11 minutes.
16
30 sec
Heating
Operation
–6
Deice
Operation
–7
Starting
Signal
–9
–11
40Hz (CU-G93KE)
Free
49Hz (CU-G123KE)
ON
ON
ON
ON
ON
ON
Deice Operation
Ending
Signal
30
sec
Deice max 11 min
58Hz (CU-G93KE)
83Hz (CU-G123KE)
OFF
OFF
OFF
OFF
OFF
OFF
– 27 –
30 sec
Heating
Operation
99Hz
(CU-G93KE)
OFF
115Hz
(CU-G123KE)
OFF
Hot Start
OFF
ON
OFF
ON