Operation Details
4. HEATING OPERATION
A. Room Temperature Control
•
During heating operation, the room temperature control depends on intake air temperature and internal
setting temperature. Basically it can be divided into 2 periods as shown below:
(i) When indoor fan speed is Medium or above.
CS-G93KE
Heating Operation
Remote Control Setting Temp.
Intake air temperature –
Internal setting temperature
Compressor OFF
Internal setting temp.
Outdoor air temperature
Intake air temp. – internal setting temp.
Transition Period
16°C ~ 30°C
Comp Off
+1.5
15
+1.0
15
+0.5
22
0
46
–0.5
53
–1.0
64
–1.5
71 (Fh) or
99 (Fhmax)
Stabilized
0°C
period
Transition
period
Compressor Operation Frequency (Hz)
Stabilized Period
16°C ~ 20°C
Comp Off
Comp Off
15
15
15
15
22
22
26
26
33
33
36
36
71 (Fh) or
71 (Fh) or
99 (Fhmax)
99 (Fhmax)
Less than
–1°C and
–1°C
above
– 22 –
CS-G93KE
–1.5°C
21°C ~ 30°C
Comp Off
Comp Off
15
15
26
15
33
22
36
26
46
33
53
36
71 (Fh) or
71 (Fh) or
99 (Fhmax)
99 (Fhmax)
Less than
–1°C and
–1°C
above