Heating Operation - Panasonic CS-G93KE Service Manual

Table of Contents

Advertisement

Operation Details

4. HEATING OPERATION

A. Room Temperature Control
During heating operation, the room temperature control depends on intake air temperature and internal
setting temperature. Basically it can be divided into 2 periods as shown below:
(i) When indoor fan speed is Medium or above.
CS-G93KE
Heating Operation
Remote Control Setting Temp.
Intake air temperature –
Internal setting temperature
Compressor OFF
Internal setting temp.
Outdoor air temperature
Intake air temp. – internal setting temp.
Transition Period
16°C ~ 30°C
Comp Off
+1.5
15
+1.0
15
+0.5
22
0
46
–0.5
53
–1.0
64
–1.5
71 (Fh) or
99 (Fhmax)
Stabilized
0°C
period
Transition
period
Compressor Operation Frequency (Hz)
Stabilized Period
16°C ~ 20°C
Comp Off
Comp Off
15
15
15
15
22
22
26
26
33
33
36
36
71 (Fh) or
71 (Fh) or
99 (Fhmax)
99 (Fhmax)
Less than
–1°C and
–1°C
above
– 22 –
CS-G93KE
–1.5°C
21°C ~ 30°C
Comp Off
Comp Off
15
15
26
15
33
22
36
26
46
33
53
36
71 (Fh) or
71 (Fh) or
99 (Fhmax)
99 (Fhmax)
Less than
–1°C and
–1°C
above