Pitney Bowes da95f Operator's Manual page 54

Addressright da series printer
Hide thumbs Also See for da95f:
Table of Contents

Advertisement

3 • Printer Maintenance
Example 1
The gap is EQUAL to .25 in (6.35 mm)
No adjustment is needed.
MOD TO SENSOR
*
01.600 inches
Example 2
The gap is LESS than .25 in (6.35 mm)
a. Subtract the measurement on the
test pattern from .25in (6.35mm)
b. Decrease the number on the display
by the answer from step a.
.25 - .15 = .1
In this example, you would decrease
the number on the display by .1 from 1.6 to 1.5
MOD TO SENSOR
*
01.500 inches
Example 3
The gap is GREATER than .25 in (6.35 mm)
a. Subtract .25in (6.35mm) from
the measurement on the test pattern.
b. Increase the number on the display
by the answer from step a.
.35 - .25 = .1
In this example, you would increase
the number on the display by .1 from 1.6 to 1.7
MOD TO SENSOR
*
01.700 inches
3-10