(b)
Pull-in Test
The
pull-in
coil
is
judged
as
normal
if
the
plunger
is
attracted
and
the
pInIon
comes
out when the battery is connected
between
the
solenoid
terminals
(S) and (M).
CAUTION:
Do
continuously
10 seconds.
(c)
Holding Test
not
apply
voltage
for
more
than
Wi th
the battery connected bet-
ween
the
solenoid
terminal
(S)
and the body, pullout the pinion
by
hand
as
far
as
the
pinion
stopper.
If the pinion does not
return when released, the holding
coil is considered normal.
CAUTION:
Do
not
apply
voltage
continuously
for
more
than
10 seconds.
(d)
Return Test
With
the
battery
connected
be-
tween the solenoid terminal
(M)
and the body, pullout the pinion
by
hand
as
far
as
the
pinion
stopper.
If the pinion returns
immediately when
released,
both
coils are considered as normal.
CAUTION:
Do
not
apply
voltage
continuously
for
more
that
10 seconds.
(5)
Checking of Pinion Gap
If the battery is connected be-
tween
the
solenoid
terminal
(5)
and
the starter body, the pinion will jump
out and stop.
In such a state, push
the
pinion
lightly
back
toward
the
armature and measure the gap between
the
pinion
and
the
stop
ring.
(Measured value of pinion gap should
be 0.5 -2.0 mm.)