Console Server Port Configuration - Lindy SC5-4xIP User Manual

Table of Contents

Advertisement

Console server port configuration

This extra sub-screen allows you to adjust the serial port settings for any of the
ports that are using Console CAMs or the OPTIONS port when it is configured as
a 'Console Server' connection.
Notes:
If a port has neither the Telnet or SSH support options selected, it is greyed out.
Port 0 (the Options Port) will remain greyed out if the
page has its Options port use to set to any setting other than 'Console Server'.
To get here
1 Using VNC viewer or a browser, log on as the 'admin' user.
2 Click the 'Configure' button in the top right corner.
3 Click the 'Console Server Configuration' option.
4 Click the 'Edit Port Configuration' button.
Serial Configuration
Baud
Available baud rates for each port: 1200, 9600 or 19200.
Parity
Available parity settings: None, Odd or Even.
FlowCtrl
Available flow control options: None, Hardware (RTS/CTS) or
Software (XON/XOFF).
Data/Stop
Available data word and stop bit combinations: 7/1, 7/2, 8/1 or 8/2.
Telnet
Determines whether the associated port can be connected to using the Telnet
protocol. If neither this nor the SSH box are ticked for a port, then the port will
remain greyed out.
SSH
Determines whether the associated port can be connected to using the SSH
(Secure SHell) protocol. If neither this nor the Telnet box are ticked for a port,
then the port will remain greyed out.