What to do if the ADMIN password has been forgotten
If the ADMIN password becomes mislaid or forgotten, you will not be able to
access the SC5-4xIP to add or edit users and computer names, unless you have
given other users admin privileges. This situation may be resolved by performing
a complete reset to return the SC5-4xIP to factory settings.
IMPORTANT: A complete reset erases all the user names and computer
names that you have setup.
To clear a password (and restore factory default settings)
1 Remove power from the SC5-4xIP unit.
2 Press and hold the reset button on the
front panel (requires paper clip or similar).
3 Apply power and after a couple of
seconds release the reset button. The
Maintenance menu will be displayed
4 Highlight 'Reset Configuration' and
press
. The Reset Config warning will
be displayed
5 Highlight 'Reset' and press
settings will be returned to their factory
defaults and the previous Maintenance
menu will be re-displayed.
6 Remove power from the unit and then
re-apply it.
7 You now need to go through the
configuration procedure
and re-
instate all of the required settings.