Tadiran Telecom TGW1E1-2G User Configuration Manual

Tadiran Telecom TGW1E1-2G User Configuration Manual

Trunk gateway series
Table of Contents

Advertisement

TGWxE1-2G
PRI (ISDN)
Trunk Gateway Series
User Configuration Manual
TGW1E1-2G
TGW2E1-2G
TGW4E1-2G
Document Edition 2.1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TGW1E1-2G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tadiran Telecom TGW1E1-2G

  • Page 1 TGWxE1-2G PRI (ISDN) Trunk Gateway Series User Configuration Manual TGW1E1-2G TGW2E1-2G TGW4E1-2G Document Edition 2.1...
  • Page 2 The information contained in this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreement protecting TADIRAN TELECOM (TTL) L.P.’s (herein referred to as the “Manufacturer”) rights in the aforesaid information. Neither this document nor the information contained herein may be published, reproduced or disclosed to third parties, in whole or in part, without the express, prior, written permission of the Manufacturer.
  • Page 3: Record Of Changes

    Date Oct-6-2015 Added US ALARMS database requirements Aug-30-2015 edition TGW1E1-2G, TGW2E1-2G, TGW4E1-2G Based on NR Document No.: MB5-E001-P, Document Version: 201504 Document Rev. 01 (Apr, 2015 ) The TGW gateways support centralized auto provision. This will be supported as part of Aeonix version 3.
  • Page 5: Table Of Contents

    Table of Contents Table of Contents ............................. i List of Figures ..............................iv List of Tables ..............................vi 1 Overview ..............................1-1 1.1 Product Introduction ............................1-1 1.2 Features ................................1-1 1.3 Equipment Structure ............................1-3 1.3.1 Front & Back Panel ..........................1-3 1.3.2 CON Port ..............................
  • Page 6 5 TGW Configuration ............................ 5-1 5.1 Login .................................. 5-1 5.2 Buttons Used on Gateway Management Interface ..................... 5-2 5.3 Basic Configuration ............................5-3 5.3.1 Network Configuration ..........................5-3 5.3.2 System Configuration ..........................5-6 5.3.3 SIP Configuration ........................... 5-8 5.3.4 TDM Configuration ..........................5-10 5.3.5 FoIP ..............................
  • Page 7 8 Appendix: Quick Configuration Procedure .................... 8-1 8.1 Gateway Unit Configuration ..........................8-1 8.1.1 Basic Configuration ..........................8-1 8.1.2 Advanced Configuration ......................... 8-4 8.1.3 ISDN Configuration ..........................8-6 8.2 Aeonix Configuration ............................8-6 8.3 Verification ................................. 8-6...
  • Page 8: List Of Figures

    List of Figures Figure 1-1 Front Panel ............................. 1-3 Figure 1-2 Back Panel ............................. 1-4 Figure 1-3 RJ45 to RS232 serial cable ........................1-5 Figure 1-4 USB to RS232 converter cable ....................... 1-5 Figure 3-1 Installation of TGWxE1-2G Series L-shape Brackets ................3-1 Figure 3-2 Mount TGWxE1-2G to Rack ........................
  • Page 9 Figure 7-1 ISDN1 Configuration Interface ........................ 7-1...
  • Page 10: List Of Tables

    List of Tables Table 1-1 Front Panel .............................. 1-3 Table 1-2 Indicators ..............................1-3 Table 1-3 Pinouts of Ethernet Ports ......................... 1-4 Table 1-4 Pinouts of T1/E1 Module.......................... 1-4 Table 1-5 Description of Back Panel ........................1-4 Table 1-6 Standard Table for Lead Wire of Pin at Configuration Port (CON) ............1-5 Table 1-7 Attributes of CON Port ..........................
  • Page 11: Overview

    User Configuration Manual Overview 1.1 Product Introduction The TGW1E1-2G, TGW2E1-2G, and TGW4E1-2G (herein referred to as the “TGWxE1-2G”) SIP-ISDN trunking gateway is one of VoIP gateway product series for Aeonix UC&C It uses SIP and T1/E1 interfaces for the inter-conversion of IP packets and PCM signals, allowing the interworking of the IP-based Aeonix UC&C voice network with legacy Public Switched Telephone Network (PSTN), and the...
  • Page 12 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual time between failures (MTBF), including features such as redundant power supply option and dual Ethernet ports. In addition, the TGWxE1-2G uses a Web-based graphical management interface to facilitate user configuration and routine maintenance. Low cost and high reward How to reduce cost and investment risk is one of the major challenges a user faces when choosing an IP-based new generation voice device.
  • Page 13: Equipment Structure

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 1.3 Equipment Structure 1.3.1 Front & Back Panel Figure 1-1 Front Panel Table 1-1 Front Panel Item Mark Description Pressing the RST button for less than 3 sec: no action will be taken. ①...
  • Page 14: Figure 1-2 Back Panel

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Mark Function Status Description Flashing Green System is operating normally Green No alarms Alarm Indicator Flashing Red New alarms occurred Alarms exist Green On The transmit speed is 1000M bit/s. Green Off The transmit speed is 10M bit/s or 100M bit/s.
  • Page 15: Con Port

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 1.3.2 CON Port The TGWxE1-2G provides one configuration interface (CON) of RJ45 interface for local management and debugging. Table 1-6 Standard Table for Lead Wire of Pin at Configuration Port (CON) Pin number of RJ45 plug Description Pairing connection with DB9...
  • Page 16: Specifications

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 1.3.3 Specifications Table 1-8 Specifications Item Description Basic Ethernet RJ45, 4×10/100/1000M Base-T, self-adaptive E1/T1Interface 4, 120 simultaneous VoIP calls SD Interface CON Interface RJ45 System Memory 256MB System Flash 32MB Processor TI AM3352...
  • Page 17: Installation Preparation

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Installation Preparation To avoid personal injury and TGW damage, please read this chapter carefully before installation. 2.1 Installation Precautions For your safety, please follow the precautions when TGWxE1-2G is installed and used. Keep the site free from heat and humidity ...
  • Page 18: Power Supply

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual To ensure adequate ventilation to keep the gateway from overheating, there should be adequate clearance for the air intake and the air exhaust vents. Keep at least 6 cm clearance at the left and right side of the chassis where the air intake is and at least 15 cm clearance at the rear of the chassis where the exhaust vents are located.
  • Page 19: Opening Inspection

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 2.3 Opening Inspection After the completion of installation preparation, you should open the box for inspection. Make sure the gateway and all in-box accessories match the description below. A TGWxE1-2G with basic configuration should include components as shown in the following table. Table 2-1 Standard Configuration Description Quantity...
  • Page 21: Installation Procedure

    TGWxE1-2G PRI (ISDN) Trunk Gateway Series for Aeonix User Configuration Manual Installation Procedure 3.1 Tools and Meters Screwdriver  Antistatic wrist strap  Ethernet and console port cables  Power cable  Terminals (a PC running terminal program can be used) ...
  • Page 22: Figure 3-2 Mount Tgwxe1-2G To Rack

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Follow the steps to install the gateway: Place the gateway on a shelf in the rack.  Slide it to the proper position along the guide rails.  Fix the rack-mount brackets to the rack posts with supplied Phillips screws. Make sure that the ...
  • Page 23: Installing Cables

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 3.3 Installing Cables 3.3.1 Connecting Console Port A CON should be provided with the TGWxE1-2G to check errors of the TGW. Connect the CON with the computer’s RS232 serial ports, so local computers can interwork with the TGW through simulating terminal programs.
  • Page 24: Connecting The T1/E1 Cable

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 3.3.3 Connecting the T1/E1 Cable TGWxE1-2G offers an RJ45 jack as the T1/E1 connector for making ISDN connection with the Aeonix. Please identify the connector type and interface impedance of the other side equipment before making the T1/E1 connection.
  • Page 25: Connecting The Power Cord

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 3.3.5 Connecting the Power Cord Before connecting the power cord, make sure the AC power outlet has a protective earth contact and the earth contact of the AC power source is properly grounded. Please contact your manufacurer’s representative if the power LED does not light up after the power is turned on.
  • Page 27: Powering Up The Gateway

    TGWxE1-2G PRI (ISDN) Trunk Gateway Series for Aeonix User Configuration Manual Powering up the Gateway 4.1 Verification before Power-up 4.1.1 Checklist This is a review process of the installation work, including the chassis, wiring, connectors, ports, labels and site as described in the subsections. Gateway Check whether there is adequate clearance around the gateway for heat dissipation, and whether the ...
  • Page 29: Tgw Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateway Series for Aeonix User Configuration Manual TGW Configuration 5.1 Login Double-click the icon to open IE browser, and enter the gateway IP address in the browser address bar (eg. 192.168.2.240). You can enter the login interface for gateway configuration by entering a password on the login interface.
  • Page 30: Buttons Used On Gateway Management Interface

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.2 Buttons Used on Gateway Management Interface Submit buttons are located at the bottom of the configuration screens. It is used to submit configuration information. Users click the Submit button after completion of parameter configuration on a page. A success prompt will be displayed if configuration information is accepted by the system;...
  • Page 31: Basic Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.3 Basic Configuration 5.3.1 Network Configuration Click the Basic > Network tab to open the network configuration interface. Figure 5-2 Network Configuration Interface Table 5-1 Network Configuration Interface Note: * indicates mandatory parameters for Aeonix. Name Description Host name...
  • Page 32 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description The subnet mask is used with an IP address. When the TGWxE1 gateway uses a static IP address of ETH, this parameter must be entered. Netmask Gateway IP address LAN gateway IP address where the TGWxE1-2G gateway is located.
  • Page 33 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description Time Zone Select a time zone: (GMT-11:00) Midway Island  (GMT-10:00) Honolulu, Hawaii  (GMT-09:00) Anchorage, Alaska  (GMT-08:00) Tijuana  (GMT-06:00) Denver  (GMT-06:00) Mexico City ...
  • Page 34: System Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.3.2 System Configuration Click the Basic > System tab to open the system configuration interface. Figure 5-3 System Configuration Interface Table 5-2 System Configuration Parameters Note: * indicates mandatory parameters for Aeonix. Name Description Codec methods supported by the gateways include: G729A/20, G723/30, PCMU/20, PCMA/20,...
  • Page 35: Table 5-3 Codec Methods Supported By Gateway

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description This parameter sets the off time (ms) of DTMF signals sent from the FXO port. DTMF off-time The default is 100ms. Generally, the interval time should be set in the range of 80-150ms. For Aeonix ...
  • Page 36: Sip Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.3.3 SIP Configuration Click the Basic> SIP tab to open the SIP configuration interface. Figure 5-4 SIP Configuration Interace Table 5-4 SIP Configuration Parameters Note: * indicates mandatory parameters for Aeonix. Name Description Configure the UDP port for transmitting and receiving SIP messages, with its default value...
  • Page 37: Table 5-5 Sip Trunk User Name / Password

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description Select the check box to enable and set the parameter OPTIONS request period. The TGW detects the failure condition of the proxy server (primary server) by periodically sending OPTIONS request to it.
  • Page 38: Tdm Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.3.4 TDM Configuration In case of full configurations, the TGWxE1-2G has one 4T1/E1 card, with four interfaces numbering TDM1 to TDM4 from left to right. It is recommended to set parameters corresponding to the interface configured.
  • Page 39: Table 5-7 Operated Numbers And Translation Rules

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description Number Transformation on each T1/E1 link. Rule format for number transformation on a single T1/E1 link: Operated number: Operation rule set/Operated number: Operation rule set For details about operated numbers and translation rules, see Table 5-7. Note: The GUI shows Digit transformation.
  • Page 40 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Requirements Substitute the prefix 66 in the called numbers of calls to ISDN1 with the prefix 71.  For calls from ISDN1, delete the first two digits of the calling numbers that start with the prefix 88. ...
  • Page 41: Foip

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.3.5 FoIP Click the Basic >FoIP tab to open the FoIP configuration interface. Figure 5-6 FoIP Configuration Interface Table 5-8 FoIP Configuration Parameters Note: * indicates mandatory parameters for Aeonix. Name Description Both T.38 and T.30 fax services are supported.
  • Page 42: Isdn

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.4 ISDN In case of full configurations, the TGWxE1-2G has one 4T1/E1 card, with four interfaces numbering ISDN1 to ISDN4 from left to right. It is recommended to set parameters corresponding to the interface configured.
  • Page 43: Figure 5-8 Isdn Configuration Interface 1 (Including Link Data Configuration)

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Figure 5-8 ISDN Configuration Interface 1 (including Link Data Configuration) Table 5-9 ISDN Configuration Parameters Name Description Name Displays the name of the ISDN interface. Enable Enable an ISDN interface. Application Collecting CDPN Select the collecting mode: Overlap or Enbloc.
  • Page 44 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description Search mode of idle timeslot: Forward, Backward and Cycle. Users can select from the drop-down box. Forward: In case of an incoming call, the TGWxE1-2G first checks whether ...
  • Page 45: Figure 5-9 Isdn Configuration Interface 1 (Isdn-B Channel)

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description Displays the indicator status of a specific ISDN-B channel. If you click the channel in green, the indicator turns yellow and the call from IP to  ISDN on the T1/E1 line is prohibited.
  • Page 46: Advanced Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5 Advanced Configuration Click the Advanced tab to open the Advance options interface. 5.5.1 Routing Table 5.5.2 Application Examples of Routing Table 5.5.3 IP Table 5.5.4 Digit Map 5.5.5 System 5.5.6 Security 5.5.7 White List 5.5.8 Media Stream...
  • Page 47: Routing Table

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.1 Routing Table Click the Advanced > Routing Table tab to open the Routing Table configuration interface. * For Aeonix US ALARMS  In order to disable the Echo Cancellation mechanism for port 2524, you should add a Routing Map rule ISDN 2524 CODEC PCMU/20/0 and for all...
  • Page 48: Table 5-10 Routing Table Format

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual The format of number transformation is: Source Number Handle [Parameter] Source Number ROUTE Destination [Parameter] The format of number transformation is: Source Number Replacement Method For example: FXS 021 REMOVE 3 means remove the prefix 021 of the called number for calls from the IP network.
  • Page 49: Table 5-11 Number Transformations

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Table 5-11 Number Transformations Processing Mode Description and Example Keep number. The positive number after KEEP means to keep several digits at the beginning of the number; the negative number means to keep several digits at the end of the number. Example: IP 02161202700 KEEP -8 KEEP Keep the last 8 digits of the called number 02161202700 for calls from IP.
  • Page 50: Table 5-12 Routing Destination

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Processing Mode Description and Example Designate the use of codec, such as PCMU/20/16, where PCMU denotes G.711, /20 denotes RTP package interval of 20ms, and /16 denotes echo cancellation with 16ms window. PCMU/20/0 should be used if echo cancellation is not required to activate.
  • Page 51: Application Examples Of Routing Table

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.2 Application Examples of Routing Table Application requirements TGWxE1-2G Selecting an E1 line based on calls from the IP network.   Replacing the calling party number section of an IP call with a shared number. Permitting the IP call with the number only in the calling party number section, not other ID ...
  • Page 52: Ip Table

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.3 IP Table Click the Advanced > IP Table tab to open the IP Table configuration interface. Figure 5-11 Configuration Interface for IP Table This table is designed to ensure the safe use of gateways. Administrators can add the authorized IP addresses to this table, and the gateways will only process the information from authorized IP addresses.
  • Page 53: Digit Map

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.4 Digit Map In most situations, dialing rules need to be configured only for second dial on the TGWxE1-2G. Click the Advanced > DigitMap tab to open the Digit Map interface. Figure 5-12 Configuration Interface for Digit Map Dialing rules are used to effectively determine if the received number sequence is completed, for the purpose of stop dialing and sending out the received numbers.
  • Page 54 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Digit map Description Represents more than one digit between 0-9. The sign can match with number of any length. For example, the value 1. can match with 11 or 123.
  • Page 55: System

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.5 System Click the Advanced > System tab to open this interface. Figure 5-13 System Advanced Configuraiton Interface Table 5-14 Advanced System Configuration Parameters Note: * indicates mandatory parameters for Aeonix. Name Description Gateways support the following mechanisms for NAT traversal.
  • Page 56 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description STUN server This parameter appears when STUN is selected for NAT traversal. Set the IP or domain name of the STUN server. No default value. If the STUN server parameter is empty, the gateway will adopt the STUN server address configured at the factory.
  • Page 57: Security

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.6 Security Click the tab to open this interface. Advanced > Security Figure 5-14 Security Configuration Interface Table 5-15 Security Configuration Parameters Name Description Telnet & SSH service Select the check box to enable the Telnet service. The terminals can access the TGW through Telnet Telnet.
  • Page 58: White List

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.7 White List Click the Advanced > White list tab to open this interface. Figure 5-15 White List Configuration Interface Procedures for configuring the whitelist are as follows: Step1 Click Add.
  • Page 59: Media Stream

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.8 Media Stream Click the Advanced > Media Stream tab to open this interface. Figure 5-16 Media Stream Configuration Interface Table 5-16 Media Stream Configuration Parameters Name Description Min. RTP port The minimum value of UDP ports for RTP transmission and receiving.
  • Page 60 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description Enable VAD Only applicable to G.723, GSM, iLBC. If selected, it will not send any voice packets during mute period. By default, this parameter is selected. RTP destination address This parameter determines where to obtain the IP address of the receiving side for RTP packets.
  • Page 61: Sip Related Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.9 SIP Related Configuration Click the Advanced > SIP tab to open this interface. Figure 5-17 SIP Related Configuration Interface Table 5-17 SIP Related Configuration Parameter Name Description SIP related configuration PRACK Determines whether to activate Reliable Provisional Responses (RFC 3262).
  • Page 62: Radius [Not Applicable]

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description Calling party number in call Under call forwarding, the calling party number sent can be set to Originating number transfer or Forwarding number. The default is Forwarding number. For example: the subscriber line 2551111 on the gateway activates the call forwarding feature and sets the destination to 3224422.
  • Page 63: Call Progress Tone Plan

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.5.12 Call Progress Tone Plan Click the Advanced > Tones tab to open this interface. Figure 5-18 Tones Configuration Interface Table 5-18 Tones Configuration Parameters Note: * indicates mandatory parameters for Aeonix. Name Description There are progress tone plans for several countries and regions which are pre-programmed in...
  • Page 64: Status

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.6 Status In case of full configurations, the TGWxE1-2G has one 4T1/E1 card, with four interfaces numbering ISDN1 to ISDN4 from left to right. Users can view the ISDN calling state on the interface in usage. The calling information about ISDN (1) is used as an example.
  • Page 65: Log Management

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.7 Log Management 5.7.1 System Status Critical runtime information of gateways can be obtained in this interface, including:  The information about login interface (including IP address and permissions of the user) SIP registration status ...
  • Page 66 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description SIP Registration Info Shows registration status: Not enabled - The registration server’s address is not entered yet.  Latest response - The latest response message for the registration. 200 means ...
  • Page 67: Call Message

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.7.2 Call Message Click the Logs > Call Message tab to open this interface. Figure 5-21 Call Message Interface 5-39...
  • Page 68: Isdn Status

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.7.3 ISDN Status Click the Logs > ISDN Status tab to open this interface. Figure 5-22 ISDN Status Interface Table 5-21 ISDN Status Parameters Name Description ISDN Group ID The ID of an ISDN group.
  • Page 69 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Name Description LineCode The line code, including B8ZS, AMI, JBZS, HDB3, ZBTSI, B6ZS, JBZS, etc. LineBuildOut The line build-out, which is 120 or 75 (Ohm). ClockTiming The clock source: Local or Through. Payload The PCM encoding type: ALAW or µLAW.
  • Page 70: System Startup

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.7.4 System Startup Click the Logs > System Startup tab to open this interface. The gateway boot up information is available on this page, including the hardware configuration. Figure 5-23 System Startup Interface 5-42...
  • Page 71: Manage Log

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.7.5 Manage Log Click the Logs > Manage Log tab to open this interface. Log files can be downloaded through this interface. Figure 5-24 Manage Log Interface Table 5-22 Manage Log Parameters Name Description Log level...
  • Page 72: System Tool

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.8 System Tool 5.8.1 Change Password Click Tools to open this interface. Only administrators are entitled to change the password of login. To change the administrator password, enter a new password into the New password field and Confirm new password field, and then click Submit.
  • Page 73: Export Data

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.8.2 Export Data Click the Tools > Export data tab to open this interface. You can download the configuration files from the gateway through this interface. The download procedure is similar to the download procedure of log files.
  • Page 74: Software Upgrade

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.8.4 Software Upgrade Click the Tools > Upgrade tab to open this interface. The software upgrade procedure is as follows: Step1 Obtain the upgrade files (tar.gz file), and save the file onto a local computer. Step2 Click the Tools>Upgrade tab to access the software upgrade page.
  • Page 75: Figure 5-30 Upgrade Interface

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual Figure 5-30 Upgrade Interface Step6 The following prompt is displayed during the upgrade. Figure 5-31 Prompt of Upgrade Process The gateway upgrade takes a few minutes. Do not operate the gateway during this period. Step7 Clicke OK on the following dialog box that is displayed once the upgrade is completed.
  • Page 76: Restore Factory Settings

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.8.5 Restore Factory Settings Click Tools > Restore factory settings to restore the parameters of the gateway to factory settings. The factory settings are designed based on common applications, and therefore, no need to modify them in many deployment situations.
  • Page 77: Version Information

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 5.9 Version Information Click Info to view the gateway hardware and software version information. Figure 5-33 Version Information Interface 5.10 Logout Click Logout at the top right to exit the gateway management system and return to the login interface. 5-49...
  • Page 79: Aeonix Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateway Series for Aeonix User Configuration Manual Aeonix Configuration It is necessary to define all PRI trunks in Aeonix before any calls can be routed through them. PRI trunks must be assigned to trunk groups to operate in the Aeonix system. For detailed information, refer to the Aeonix Administration Manual.
  • Page 80: Basic Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 6.2 Basic Configuration Open the Aeonix Web Admin. Add a new trunk. a. In the navigation pane, select Administration > Trunks > Add Trunk, and then select the trunk type as SIP Trunk / Gateway. b.
  • Page 81: Status Verification

    TGWxE1-2G PRI (ISDN) Trunk Gateway Series for Aeonix User Configuration Manual Status Verification 7.1 Verification For each PRI interface in the Tadiran TGWxE1-2G gateway, you need to verify that it is registered and working OK in the status of the Gateway. 1.
  • Page 83: Appendix: Quick Configuration Procedure

    TGWxE1-2G PRI (ISDN) Trunk Gateway Series for Aeonix User Configuration Manual Appendix: Quick Configuration Procedure This chapter describes the minimal settings instructions needed to use the TGWxE1-2G gateways with Aeonix. 8.1 Gateway Unit Configuration 8.1.1 Basic Configuration 1. Connect the TGWxE1-2G unit to the network via port ETH1 or ETH2. 2.
  • Page 84 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 4. Click the Basic > System tab. For detailed information, see System Configuration on page 5-6. a) In the Codec box, type the required codecs methods to be supported by the gateway. These codecs must be set due to no default value.
  • Page 85 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual formed with either numbers or characters, and is case-sensitive. Use Table 5-5 Table 5-5 as a worksheet to make a list of Trunk User Name/Password. e) Click Submit to save changes. 6.
  • Page 86: Advanced Configuration

    TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 8.1.2 Advanced Configuration 1. Click the Advanced > Routing Table tab . For detailed information, see Routing Table on page 5-19. a) In order to disable the Echo Cancellation mechanism for port 2524, you should add a Routing Map rule ISDN 2524 CODEC PCMU/20/0 and for all ports...
  • Page 87 TGWxE1-2G PRI (ISDN) Trunk Gateways Series for Aeonix User Configuration Manual 3. Click the Advanced > Tones tab to open the configuration interface . For detailed information, see Call Progress Tone Plan on page 5-35. a) From the Country/Region drop-down list, select the system location. Note: For Aeonix US ALARMS ...
  • Page 88: Isdn Configuration

    For detailed information, see ISDN on page 5-14. Fill in the ISDN1/2/3/4 pages, according to your PRI service provider requirements. a) ISDN1 - for Tadiran TGW4E1-2G, TGW2E1-2G and TGW1E1-2G models. b) ISDN2 - only for Tadiran TGW4E1-2G and TGW2E1-2G models.
  • Page 89 TGWxE1-2G PRI (ISDN) Trunk Gateway Series for Aeonix User Configuration Manual Israel +972-3-9262000 678-506-7200 Russia +7-495-7750855 China +86-10-58696418 India +91-11-41523168 / 23353822 Visit us at: www.tadirantele.com...

This manual is also suitable for:

Tgw4e1-2gTgw2e1-2g

Table of Contents