Description of Panel Sounder:

Number of "Beeps"
[ 1 short beep]
[ 2 short beeps]
[ 3 long beeps]
[ 4 short beeps]
[ 5 short beeps]
[ 1 beep every second ]
[ 1 beep every 3 seconds ]
[ 3 beeps every minute]
Description of the alarm triggers:
A Burglary alarm trigger during "Day" mode arming (see par.09 "Zone Settings" page 19 option "Zone
Type 2"). The siren will be triggered only if the panel is armed in Day mode (see page 27).
The wireless siren trigger time and the output terminals 16, 17 and 18 are specified in the menu
"Siren Duration" under option "Motion Siren" (see page 16). To stop the alarm trigger, disarm the
control panel.
A Burglary alarm triggered during the "Night" mode arming (see par. 09 " Zone Settings" page 19
option "Zone Type 1"). The siren triggered with the panel in armed in Day and Night mode. (see page
27).
The wireless siren trigger time on the output terminals 16, 17 and 18 are determined in the menu
"Siren Duration" in the programming menu option "Perimeter Siren" (see page 16). To stop the alarm
trigger, disarm the panel.
All alarm triggers related to Emergency or Medical, Fire, Tamper etc. are armed 24 hours. The siren
activation time and that of the terminal outputs 16, 17, and 18 are determined by the programming
menu "Siren Duration" under the option "Emergency Siren" (see page 16). To stop the alarm trigger if
the panel is armed you must only disarm it but if the panel is not armed you must 1st arm and
immediately after disarm.
On the hardwire sirens there is a signal sound for all alarm triggers. The wireless sirens have
3 different alarm trigger output sounds. Continuous sound for Burglary. Bell sound for Fire and
Intermittent chirp sound for Emergency.
DUALNET—6 INSTRUCTION MANUAL
Function
Every time you press a Keypad button.
Every time you arm the panel in ( Day or
Night)
Every time the control panel is disarmed
In case of faulty telephone line or line cut.
The control panel is put in "TEST MODE"
Indicates that an Alarm Trigger has taken place.
"Walk Test" mode or "Courtesy Function "
Indicates that a delay zone has been
violated.
Indicates that the control panel has been
armed and beeps during the (Exit Time)
Indicates that there is a GSM module failure.
Indicates that a wireless sensor has a low battery. To avoid tamper alarm trigger change the
ENGLISH
Note
In the case that the PSTN tel. line is defective or
cut 2 beeps are heard every minute.
See the paragraph ???? For "Contact ID"
configuration.
After an alarm trigger, with panel disarmed,
the Zone triggered will be shown on keypad
display.
If activated, it will indicate that a zone has been
violated or that a zone is triggered. (on the
keypad you may see which one); When the
zone returns to normal status the keypad will
emit a beep..
Disarm the control panel before it is triggered.
Exit the protected area before total arming take
place.
battery with the control panel in programming
mode.
See paragraph of how to change a low battery.
Pag. 9