Control Panel Description - 3i Dualnet-6 Instruction Manual

Combined hardwired and wireless control alarm panel with incorporated telephone diallers gsm, pstn & digital
Table of Contents

Advertisement

ENGLISH

Control Panel Description:

1
2
3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
12
AUX
Z1 GND Z2 Z3 GND Z4 Z5 GND Z6
11
POWER 12VOLT
Terminal Description of function
1-2
D.C. 14 volt regulated power input through 1.8amp. on-board switching power supply.
D.C. 12 volt auxiliary power for all sensor that require 12 Vdc. Power current max 2A.
3-4
Number 6 programmable double balance line hardwire zones. All wired zone are By-passed (see pag.19)
5 to 13
14
EXT TAMPER: Balanced line input tamper terminal with end of line resistor of 2,2 KΩ.
15
PULSE KEY input. This is the remote input to Arm/Disarm the control panel. 1st pulse panel Armed,
2nd pulse panel Disarmed.
16
Normally open alarm relay. When panel is in stand-by this relay is Normally Open. When panel is trig-
gered a negative command will be present. Maximum drain 2Amp.
Output for electronic siren. This output must be connect to a common ground. No voltage present when
17
panel is in stand-by. When the panel is triggered to 13.8 Vdc. will be present for the alarm duration time.
Maximum drain 2 amp.
18
This output must be connected to a common ground. It is used to recharge the battery for sirens with back
-up batteries. With panel in Stand-by 13.8Vdc. is present with panel triggered 13.8 Vdc. will disappear
for the alarm time and the outdoor siren will trigger.
Common ground Terminal for the above 17 & 18.
19
Led "ON" This output must be used hardwired with a common ground to create a remote LED indica-
20
tion to signal Panel Armed or Disarmed.
Led "NIGHT" This output must be used with a common ground to create a remote LED indication to
21
signal panel Armed/Disarmed status in night mode.
22
12 V dc. Power to Touch Screen Keypad DN-6KP
RX / TX transmission data from Keypad to mother board.
23-24
Keypad ground connection.
25
MIC2N and MIC2P Microphone connections to keypad.
26-27
28
BEEPER Keypad buzzer connection.
Pag. 4
4
5
Z7 GND Z8 Z9 GND Z10 Z11 GND Z12 Z13 GND Z14
EXT. PULSE
NO
RELAY
SIREN
KEY ALARM ELETT. AUTO. GND
TAMPER
6
7
8
9
+12V
RX
TX
GND MIC2N MIC2P BEEP
ON NIGHT
LED
KEY PAD
DUALNET-6 MANUAL
Fig.1
230 Vca/Vac
GND
Fusibile
Fuse
10
ATTENZIONE
Rischio di scarica elettrica
CAUTION
Risk of electric shock

Advertisement

Table of Contents
loading

Table of Contents