Brief Description Of Keypad Commands - 3i Dualnet-6 Instruction Manual

Combined hardwired and wireless control alarm panel with incorporated telephone diallers gsm, pstn & digital
Table of Contents

Advertisement

ENGLISH

Brief description of keypad commands:

Command
[End user password]+[ 1 ]
[End user password ]+[ 2 ]
[End user password]+[ 3 ]
[End user password]+[ 4 ]
[End user password ]+[ 5 ]
[End user password]+[ 6 ]+ [Zone
XX]
[End user password]+[ 7 ]
[End user password]+[ 9 ]
[ #]+ [Installer password]
(*) Note: the control of the hardwire zones (from 1 to 14) is active only if the program is set in "Zone Ready"
and "YES" is selected. (See page 22). In any case the zones that are triggered when the panel is armed, will
be automatically by-passed but will become active if the zone is normalized. Example: if i have a door
open and i force arm the panel, this zone will be by-passed. If I then close the door without disarming the
panel this zone will again become active.
Command
o
Pag. 8
Function
To disarm the control panel
To arm the control panel in "Day mode"
To arm the control panel in "Night mode"
Forced "Day" arming
Alarm trigger test
By-pass Zone "XX" With control panel
armed.
Forced "Night" arming
With control panel disarmed, you may activate
or deactivate the acoustic keypad sounder. On
keypad display you see (Area cue tone)
To program the control panel.
Function
If this key is pressed, it will indicate the Zones
in which the installed sensors are triggered.
If this Key is press for 2 seconds the control
panel will generate a HOLD-UP Alarm trigger.
If this Key is pressed for 2 seconds the control
panel will generate a FIRE Alarm trigger.
If this key is pressed for 2 seconds the control
panel will generate an EMERGENCY alarm
trigger.
With control panel Armed, if these Keys are
press the GSM signal strength will be seen.
During programming, these keys are used to
navigate with-in the program menu.
Note
If you select the zone option as "Yes", the panel
will ask if you wish to Arm with a zone triggered
and if you confirm, this Zone will be automati-
cally by-pass until the panel is Disarmed and
again Armed.(*)
If you select the option "Ready to Arm" the
panel will request a confirmation if a zone is
triggered. If you select to force arm, this zone
will be automatically by-passed until it has been
normalized (*)
All zones triggered are automatically by-passed.
If normalized, the will become active again. (*)
A 3 second trigger will take place and transmitted
to the CMS by means of Contact ID, If this has
not been programmed, a message will be sent to
the memorized tel. numbers followed also by a
voice messaged if recorded.
Once the control panel is disarmed, the zone
"XX" will return to its original status.
All zones triggered are automatically by-passed.
If normalized, the will become active again. (*)
This function is active only if a zone is
programmed for this function (see "Set Smart
Zone" page 21 and 22).
The installer must use this password to enter into
programming mode. After 3 negative attempts
the control panel will return to the Disarmed
mode.
Note
DUALNET-6 MANUAL

Advertisement

Table of Contents
loading

Table of Contents