Telephone Line Tamper Control - 3i Dualnet-6 Instruction Manual

Combined hardwired and wireless control alarm panel with incorporated telephone diallers gsm, pstn & digital
Table of Contents

Advertisement

ENGLISH
"Automatic test time" indicates time
that goes by between two messages
of control panel working correctly to
the CMS
In order that this function be active you must set the display so that it will show 00010 to 99999
minutes, if the display shows this test is not in function. (from 00001 to 00009 is not accepted.)
At the end press the key
#
menu.
Note: With the above setting in function, the Dualnet-6 will send a full report of its status in a given
time period as shown on the display. This includes (Mains 230Vac, Low battery, Zone failures,
Telephone line failures, etc.) In the case of panel failure or alarm trigger, the control panel, through
the on-board telephone diallers, will send in real time, all the events taking place .

08. TELEPHONE LINE TAMPER CONTROL

Enter the programming menu and go to the window "PSTN Failure"
Press the key
E
on the display will appear:
With the keys
or
Automatically you will return to the preceding menu.
Note: By selecting "YES" on "Phone Anti-cut", if the control panel is not in programming mode and
the PSTN telephone line is not present, on the display will appear "Phone cut" and two beeps will
emitted every 7 seconds by the keypad.
Pag. 18
Auto Test Time
00000
to return to the preceding menu or the key
CMS Options
PS
TN Failure
PSTN Failure
YES NO
select " YES" or "NO" and confirm with
If this number is set to 00000
this indicates that this function is not
active
to go to the next
E
E
DUALNET-6 MANUAL