INDICATION OF HOW TO DEFINE A ZONE

ZONE
Selecting how a zone must
From 01 to 14 Hardwire
function is important.
You may select between
From 15 to 44 Wireless
24 Hours, Night and Day
This is the code attributed to
SENSOR
the sensor during program-
CODE
ming: from 01 to 15
This is the type of sensor
TYPE OF
installed which is named in
SENSOR
the trigger of an alarm.
(*) Example: if the hardwire zone expansion module (DN-8Z) is not used you must by-pass the
zone 07 to 14.
(**) See page 19 under 09 attribute the zones.
Sensor
Test shown on keypad & SMS
code
Hold up
00
Door Contact
01
Gas detector
02
Smoke detector
03
Corridor Sensor
04
Kitchen Window
05
Kitchen PIR
06
Bathroom Window
07
Bathroom PIR
08
Water detector
09
Bedroom Window
10
Bedroom PIR
11
Livingroom Contact
12
Livingroom Window
13
Livingroom PIR
14
Outdoor Sensor
15
Pag. 20
Belonging to **
Zone Bypassed
All zones that have not
been used must remain in
(BYPASS) mode (*)
Note: The sensor code 00 is
associated to the HOLD-UP
trigger button.
CID
displays
E100
E131
E112
E111
E132
E131
E132
E131
E132
E113
E131
E132
E131
E131
E132
E136
Table no. 1 Sensor Codes
DELAYED
If it is necessary to inter
into a protected zone, the
zone must be in delay
mode.
CID displays text
Emergency call
Perimeter alarm - door
Gas alarm
Smoke alarm
Motion detector alarm
Perimeter alarm - window
Motion detector alarm
Perimeter alarm - window
Motion detector alarm
Water flow alarm
Perimeter alarm - window
Motion detector alarm
Perimeter alarm - window
Perimeter alarm - window
Motion detector alarm
Perimeter alarm – outdoor PIR
DUALNET-6 MANUAL