21. Hold-up alarm trigger procedure (Distress Code):

In case of (hold-up or medical distress) it is possible to Disarm the control panel with an Emergency
code: After having entered this Emergency password, all sirens both hardwired and wireless will be
disarmed. The Dualnet-6, however, will continue to send all messages to the telephone numbers
memorized.
To totally block the control panel the End User Password must be entered.

22. Sensor low battery trigger procedure:

When a wireless sensor send a low battery transmission, the keypad will emit 3 beeps every 60
seconds.
While in programming mode go to the window "Alarm Reports" and find the position in which low
battery has been memorized. This position will indicate the sensor that has sent the low battery
transmission signal. You should now proceed to change the battery in that sensor. This must be
done with the Dualnet-6 in programming mode and it must be done in no more than 2 minutes to
avoid a tamper alarm trigger.
After this has been done exit the programming mode and test the new battery by triggering the sen-
sor to make sure that the keypad will no longer emit a 3 beeps every 60 seconds.
Repeat the above procedure if the beeps do not terminate. Also the new battery may be defective.

23. Return control panel to factory settings:

In this section is described how the control panel may be totally reset to the factory values.
In the programming menu press the digits:
#
】+【In Staller Password】+【99】+【
A long buzzer sound will be heard and the control panel will automatically be returned to its original
factory settings.
The following data will be cancelled:
All new codes will be cancelled and installed again the Fty. Codes as follows: Installers code 1234,
-
End user code 1111, Emergency code 2222)
All dialler telephone numbers will be cancelled.
-
Entrance and exit time will be set to Fty levels (10 sec.) Entrance and Exit.
-
All sirens setting will return to 60 seconds.
-
All Zone data and selections will be cancelled.
-
All Zone data and options will be cancelled.
-
All Pegaso key chain codes learned will be cancelled.
-
All Pegaso sensor codes learned will be cancelled.
-
Event alarm memory will be cancelled.
-
Event access memory will be cancelled.
-
The following will remain memorized and cancelled if over written.
The voice message.
-
CMS options
-
Date and hour
-
PSTN telephone line status.
-
Programming the wireless outdoor siren
While programming the wireless siren the control panel will show confirmation messages on the
display. Due to this, we suggest that the installer program the siren to function with the control panel
before fixing it to the wall. To do this, consult the programming instructions supplied with the siren.