E. Factory-Built Chimney
The chimney can be new or existing, and must meet the
following minimum requirements.
Must be a 6 inch (152mm) diameter (ID) high
temperature chimney listed to UL 103 HT (2100
ULC S629M.
Must use components required by the manufacturer
for installation.
Must maintain clearances required by the manufacturer
for installation.
Refer to manufacturers instructions for installation.
NOTICE: In Canada when using a factory-built chimney it must
be safety listed, Type UL103 HT (2100 o F) [1149 o C] CLASS
"A" or conforming to CAN/ULC-S629, STANDARD FOR
650 o C FACTORY-BUILT CHIMNEYS.
Listed Termination Cap
Roof Brace (if required)
Trim Collar on
Inside Wall
Chimney
Connector
Floor
Protector
Figure 13.1 - Factory-Built Exterior Chimney
WARNING
Fire Risk.
Follow Chimney Connector Manufacturer's Instructions
for Proper Installation. ONLY use connector Within the
room, between appliance and ceiling or wall.
Connector shall NOT pass through:
• Attic or roof space
Floor or ceiling
Maintain minimum clearances to combustibles
August 3, 2015
Storm Collar
Flashing
Listed Chimney
Insulated " T "
Wall Support
• Closet or similar concealed space
o
F) or
Listed Chimney
Ceiling Support
Chimney
Connector
Floor
Protector
Figure 13.2 - Factory-Built Interior Chimney
Fire Risk.
Do NOT pack insulation or other combustibles between
spacers.
• ALWAYS maintain specifi ed clearances around venting
and spacers.
Install spacers as specifi ed.
Failure to keep insulation or other material away from vent pipe
may cause fi re.
Fire Risk.
Inspection of Chimney:
Chimney must be in good condition.
Meets minimum standard of NFPA 211
Factory-built chimney must be 6 inch (152mm)
UL103 HT.
Asphyxiation Risk.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVICING ANOTHER APPLIANCE.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
May allow fl ue gases to enter the house.